HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Firmware Release Notes

HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Firmware Release Notes

Storage enclosure
Hide thumbs Also See for 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure:

Advertisement

HP StorageWorks MSA60/70 Storage
Enclosure Firmware Release Notes
Part number: 536920 003
Third edition: February 2010

Advertisement

Table of Contents
loading

Summary of Contents for HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure

  • Page 1 HP StorageWorks MSA60/70 Storage Enclosure Firmware Release Notes Part number: 536920 003 Third edition: February 2010...
  • Page 2 Legal and notice information © Copyright 2009-2010 Hewlett-Packard Development Company, L.P.
  • Page 3: Product Models

    Firmware version: 2.18 Description This firmware package delivers firmware for MSA60/70 Storage Enclosures. Installation procedures vary, depending on connection environment and user preference. For detailed installation instructions, Installation instructions. Update recommendation Recommended Supersedes All previously released firmware for HP StorageWorks MSA60/70 storage enclosures. Product models HP StorageWorks 60 Modular Smart Array (MSA60) HP StorageWorks 70 Modular Smart Array (MSA70)
  • Page 4 • Enterprise Edition and Enterprise x64 Edition • Datacenter Edition and Datacenter x64 Edition (non-program Datacenter) • Windows HPC Server 2008 • Microsoft Windows Server 2003/R2 (Std. & EE, both 32 & 64-bit) • Microsoft Windows Server 2003/R2 SBS • Microsoft Windows Server 2003/R2 Web Edition •...
  • Page 5: Important Notes

    Important notes IMPORTANT: If currently-installed MSA70 firmware version is less than 1.50, you must first obtain a new backplane to perform this update. If currently-installed MSA70 firmware version is less than 2.00, you must perform this update with only one I/O module inserted at a time. NOTE: After the firmware has been updated, you must power cycle each enclosure to complete the update process.
  • Page 6 Installation instructions for server-connect environments Follow instructions in this section to update firmware when the drive enclosure is connected directly to a Smart Array controller installed in a server. • Smart Component installation instructions for Windows environments Smart Component installation instructions for Windows environments Install this firmware update using the HP ProLiant Firmware Maintenance CD version 8.00 or greater.
  • Page 7 Installation instructions for controller enclosure connect environments Follow instructions in this section to update firmware when the MSA70 storage enclosure is connected to a controller enclosure, which in turn is connected to a server or network. • Smart Component installation instructions for Windows environments •...
  • Page 8 Smart Component installation instructions for Linux environments Place the Smart Component in a temporary directory. Open a Linux command console. From the directory containing the downloaded file, enable execute access to this model by typing chmod +x CPxxxxxx.scexe, where CPxxxxxx.scexe represents the downloaded file. Execute the Smart Component by entering a command similar to the following: ./ CPxxxxxx.scexe --target <ip_address>...
  • Page 9: Effective Date

    Binary file installation instructions using FTP NOTE: It takes approximately 10 minutes for the firmware to load and for the automatic restart to complete. Progress messages are displayed in the FTP interface during that time. Wait for the progress messages to specify that the firmware load has completed.