Error Information Indicated With Sense Data; Table 7.1 Definition Of Sense Data - Fujitsu MAN3184MC - Enterprise 18.4 GB Hard Drive Product/Maintenance Manual

Manual/user guide
Table of Contents

Advertisement

7.2
Sense Data Analysis
7.2.1

Error information indicated with sense data

Subsection 7.2.2 onwards explain troubleshooting using sense data.
Table 7.1 lists the definition of sense data. For details of sense data, refer to the SCSI
Logical Interface Specifications.
Sense data
Sense
Sense
Sub
key
Code
Sense
Code
00
00
00
3
0C
03
4
32
01
40
xx
44
xx
C4
xx
1
1x
xx
3
1x
xx
E
1D
00
5
2x
xx
3D
00
90
00
B
47
xx
B
49
00
B
4D
xx
B
4E
00
Table 7.1
Definition of sense data
Operation was normal.
A write to a disk terminated abnormally.
Failed to update the defect list due to a disk medium write error, etc.
An error occurred in power-on self-diagnosis.
A hardware error occurred inside IDD.
A drive error occurred.
A disk read error occurred.
A disk read error occurred.
Data discrepancy found by VERIFY command byte check.
An SCSI error, such as an invalid operation code, occurred.
The Reserve bit of the IDENTIFY message was set to 1.
The RESERVE or RELEASE command cannot be executed because
the SCSI ID of the INIT was not posted in the SELECTION phase.
A parity error occurred in the SCSI data bus.
An unmounted or inappropriate message was received.
Before completion of a command, a command with the same tag
number was issued.
An overlap command was issued.
C141-E128-01EN
Definition
7 - 3

Advertisement

Table of Contents
loading

Table of Contents