c. Hold the battery card assembly with the battery side up and the J2 board-to-board connector lining
up with the J7 BBU connector
onto the RAID controller so that the two connectors are firmly joined. Then, secure the battery
card assembly to the RAID controller with the three screws and the standoffs that come with the
battery card assembly accessory kit.
Figure 32. Installing the battery card assembly
5. See "Installing a PCI card" on page 53 and follow those instructions to install the RAID controller.
6. Connect the mini SAS signal cables to the RAID controller and the backplane by doing the following:
Note: Use the 200 mm (7.87 inches) mini-SAS signal cable.
Figure 33. Connecting the mini-SAS signal cable
1
Port 0-3 on the RAID controller
2
SAS connector
a. Connect one end
b. Connect the other end
backplane. See "Locating connectors on the backplane" on page 34.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the installation, go to "Completing the parts replacement" on page 87.
62
ThinkServer RD230 Hardware Maintenance Manual
1
on the RAID controller. Carefully press the battery card assembly
3
Label for the mini-SAS signal cable
4
SAS connector
2
of the mini-SAS signal cable to the port 0-3 on the RAID controller.
4
of the mini-SAS signal cable to the mini-SAS signal connector on the