Switch Settings; Led Indicators - Bosch TriTech+ ISC-PDL1-WA18G Installation Instructions Manual

Professional series tritech+ detector
Hide thumbs Also See for TriTech+ ISC-PDL1-WA18G:

Advertisement

3.0 Switch Settings

3.1
Switch 1 - Walk Test
��
��
���
Voltage on WT
Switch 1
ON
ON
OFF
OFF
The Remote Self Test automatically occurs when the walk
test changes from a disabled to enabled by a change in the
voltage on the WT terminals.
A passing Remote Self Test responds with an
alarm signal.
The Remote Self Test must be connected to 0 or +12 VDC
on UL listed Control Panels.
3.2
Switch 2 - Alarm Memory Polarity
��
��
���
Voltage on S/U
Switch 2
ON
ON
OFF
OFF
The Alarm Memory must be connected to 0 or +12 VDC on
UL listed control panels.
4
���
� � � �
Walk Test
Terminal
0
ON
+12
OFF
0
OFF
+12
ON
���
� � � �
Alarm Memory
Terminal
+12
ON (Locked)
0
OFF (Unlocked)
0
ON (Locked)
+12
OFF (Unlocked)
3.3
Switch 3 - Short Range/
Long Range
��
��
���
Switch 3
ON
OFF
3.4
Switch 4 - Antimask ON/
Antimask OFF
��
��
���
Switch 4
ON
OFF
When Antimask is ON, items placed witihin 1 ft (30 cm)
of the detector are detected. The detector closes the
Trouble contact (terminals marked "TR") 30 sec after
the detector is blocked.

4.0 LED Indicators

Color
Indication
Blue
Steady ON
Yellow
Steady ON
Red
Steady ON
Blue
Flashing
Flashing 1/4
Blue
sec ON, 1/4
sec OFF
Blue
3 Flashes
Blue
4 Flashes
Blue
5 Flashes
© 2009 Bosch Security Systems, Inc.
���
� � � �
Range
Distance
Short
25 ft (8 m)
Long
60 ft (18 m)
���
� � � �
Antimask
ON
OFF
Function
New alarm detected
Microwave detection
PIR Detection
Detector warming up.
(Up to 2 minutes)
Alarm Memory
Antimask Detected
Self Test/
Self Test failure
Low Input Power