Trouble
Trouble [1] Service Required
[1] Low Battery
[2] Bell Circuit
[3] General System Trouble
[4] General System Tamper
[5] Module Supervision
[6] RF Jam Detected
[7] PC5204 Low Battery
[8] PC5204 AC Failure
Cause
Press [1] to determine specific trouble
Main panel battery less than 11 V
NOTE: This trouble condition will not
clear until the battery voltage is
12.5V
min., under load.
DC
Bell+, Bell-...Open Circuit
PC5204 Output#1 Open Circuit
PC5204 AUX
Printer connected to PC5400 offline
T-Link Network Fault present
T-Link Receiver Trouble present
T-Link Interface Trouble present
Tamper input on module(s) open
circuit
Wireless Receiver - excessive noise
detected
Panel does not communicate with
module(s) on KEYBUS
Keypad assigned to incorrect slot.
Wireless Receiver - excessive noise
detected.
PC5204 battery less than 11.5V
NOTE: This trouble condition will not
clear until the battery voltage is
12.5V
min., under load.
DC
No AC at PC5204 AC inputs

Troubleshooting

NOTE: If battery is new allow 1 Hr. for battery to charge.
DC
Verify voltage measured across AC terminals is
16-18 V
. Replace transformer if required.
AC
Disconnect battery wire leads
• Verify battery charging voltage measured across bat-
tery leads = 13.70 - 13.80 V
Connect battery, remove AC power
• Verify measured voltage across battery terminals is
12.5V
min.
DC
Disconnect Bell-/Bell+ wire leads, measure resistance
of wire leads.
• Open circuit indicates break in wiring or defective
siren/bell
Jumper Bell+, Bell- with 1K resistor (Brown, Black, Red)
• Verify trouble clears
If Output#1 is unused: Ensure that terminals O1, AUX
are jumpered with 1K resistor (Brown, Black, Red)
If Output #1 is used: Disconnect wire leads from O1,
AUX terminals, measure the resistance of the wire leads
• Open circuit indicates a break in the wiring
Verify voltage measured across AC input terminals is
16-18V
.
AC
Disconnect all connections to PC5204 AUX terminal.
• Verify AUX voltage is 13.70 - 13.80 V
Verify printer operation (out of paper, paper jam etc.)
Refer to the T-Link TL250/350 Installation Manual for details.
Short tamper terminal to COM terminal on unused modules
connected to KEYBUS (PC5100, PC5108, PC5200,
PC5204, PC5208, PC5320, PC5400, PC5700).
Check for external 433MHZ signal sources
To disable RF Jam: enable Option [7] in program section
[804] subsection [90].
Modules are immediately enrolled and supervised when
detected on the KEYBUS. If a module has been removed, or
if the slot assignment of a keypad has been changed, mod-
ule supervision must be reset.
View the event buffer (via DLS or LCD5500 keypad) to
identify the specific module(s) in trouble
To reset module supervision:
• Enter Program Section [902].
• Press [#] (wait 1 minute for panel to scan KEYBUS).
Enter Program Section [903] to identify modules
connected to KEYBUS.
Check for external 433MHZ signal sources
To disable RF Jam: enable Option [7] in program section
[804] subsection [90].
See [1] Low Battery above
DC
Verify voltage measured across AC terminals is 16-18V
Replace transformer if required.
.
DC
.
DC
.
AC