STOVE STOPS FEEDING PELLETS AND SHOWS
WARNING CODE "H"
Possible Causes:
1.
One of the two L-250 automatic high temperature switch has
tripped.
CODE
BEFORE RESETING
H1, H2, H3
Heat exchanger and/or exhaust system
OR H4
is/are clogged. Refer to the owner's manual
for maintenance procedures.
*** After 3 attempts, reset is no longer possible. Call SBI technical support.
STOVE STOPS FEEDING PELLETS AND SHOWS
WARNING CODE "d"
Possible Causes:
1.
The hopper lid has stayed open for more than 3 minutes

SMOKE SMELL COMING BACK INTO THE HOME

Possible Causes:
1.
There is a leak in the vent pipe system.
2.
The gasket on the combustion/exhaust blower housing has
gone bad.

AUGER MOTOR STOPS FEEDING PELLETS AND COMES BACK ON

Possible Causes:
1.
The auger motor is overheating
and
tripping
the
internal
temperature
shutoff
(thermal
protector).
Possible Remedies:
Start by emptying the hopper. Follow procedure described in warning code "E" section #6.
Possible Remedies:
he L-250 automatic high temperature switches are located on
T
the top and bottom of the auger housing They send a signal to the
control board if the auger housing overheats.
stove cools down AND THEN INSPECT YOUR UNIT.
Improper installation, poor maintenance, or a defective or
missing component may be causing the stove to overheat. Reset
the stove and restart it. Call a technician if you get this code
again.
*See procedure below to restart the stove.
TO RESET
Press simultaneously for 2 seconds the reset
icons .
Possible Remedies:
As a security measure, the auger will stop turning and feeding pellets as
soon as the hopper lid opens. It will resume normal operation as soon as
the hopper lid is closed. However, if the hopper lid stays open for more
than 3 minutes, the unit will stop and a code "d" will appear on the control
board. Close the hopper lid. Reset the unit and start it again.
Possible Remedies:
Inspect all vent pipe connections. Make sure they are sealed with RTV
silicone that has a temperature rating on 500
with UL-181-AP foil tape.
Inspect the gasket on the combustion/exhaust blower housing to make
sure it is in good shape and replace if necessary.