Page 1
MODEL ECO-35 FREESTANDING OWNER’S MANUAL • Warning: If your appliance is not properly installed a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.
INTRODUCTION Thank you for purchasing the ECO-35 pellet stove. You are now prepared to burn wood in the most efficient, convenient way possible. To achieve the safest, most efficient and most enjoyable performance from your stove, you must do three things: 1) Install it properly; 2) Operate it correctly;...
TABLE OF CONTENTS INTRODUCTION...2 SAFETY PRECAUTIONS...3 TABLE OF CONTENTS...4 STOVE INSTALLATION ...6 ECO-35 FREESTANDING PELLET STOVE...6 CLEARANCES ...6 COMBUSTION AIR SUPPLY ...7 WHEN OUTSIDE AIR IS NOT USED ...7 VENTING ...7 EQUIVALENT VENT LENGHT (EVL) ...8 INSTALLATION CONFIGURATIONS ...8 HORIZONTALLY THROUGH WALL ...8 VERTICALLY WITH NEW CHIMNEY SYSTEM...9...
Page 5
STOVE SHUTS OFF AND SHOWS WARNING CODE “P” ...20 STOVE SHUTS OFF AND DISPLAYS WARNING CODE “E”...21 STOVE FEEDS PELLETS, BUT WILL NOT IGNITE AND SHOWS WARNING CODE “L” ...22 STOVE FEEDS PELLETS, BUT WILL NOT IGNITE AND SHOWS WARNING CODE “I”...22 STOVE STOPS FEEDING PELLETS AND SHOWS WARNING CODE “O”...22...
The coil handle must be attached to handle rod CLEARANCES The ECO-35 has been tested and listed for installation in regular and mobile homes.(refer figure 1 & 2) FLOOR PROTECTION: minimum 6” in the front and 6” on each side. The stove must be placed on a continuous (grouted joints) non-combustible material such as ceramic tile, cement board, brick, 3/8”...
VENTING The ECO-35 is certified for use with a vent certified to UL-103 or ULC S629M and a chimney type vent certified to UL-641 or ULC-S-609-M89 and ULC/ORD C441-M90, with 3” or 4” inner diameter. In Canada, we recommend that you use a listed pellet vent that meets the ULC S-609- M89 and ULC/ORD C441-M90 Standards.
HORIZONTALLY THROUGH WALL (refer to Figure 7 & 8) NOTE: Follow Vent chimney manufacturer’s instructions. Position stove, adhering to clearances shown in Figures 1 & 2. Locate position of hole in wall; directly behind stove exhaust vent (refer to figure 4).
OPTION: Install Vent elbow in place of clean-out tee. Locate stove. Drop plumb bob to center of tee outlet, mark point on ceiling. Install ceiling support and Vent pipe per Vent manufacturer’s instructions.
Install vent cap. INSTALLATION THROUGH SIDE OF MASONRY CHIMNEY NOTE: Follow Vent chimney manufacturer’s instructions. Position the stove, adhering to the clearances in Figures 1 & 2. Mark the center of the hole where the pipe is to pierce the masonry chimney.
High ash content – Poor quality pellets will often create smoke and dirty glass. They will create a need for more frequent maintenance. You will have to empty the burn pot plus vacuum the entire system more often. Poor quality pellets could damage the auger. DROLET cannot accept responsibility for damage due to poor quality pellets.
No fire starter is necessary to ignite the unit. The auger will feed fuel for 4 minutes and the electronic igniters will stay on for 10 minutes. If the unit doesn’t ignite within 15 minutes, the stove will wait for 5 minutes and will start a second ignition cycle.
Your stove uses a unique patented technology called COMBEX. As opposed to most other pellet stoves, which use only an exhaust blower, your ECO-35 uses a motor on which are mounted two housings with impeller blades. One housing serves for combustion, and the other for exhaust.
OR H4 is/are clogged. Refer to the owner’s manual for maintenance procedures. *** After 3 attempts, reset is no longer possible, call SBI technical support. DAMPER OPERATION will appear. TO RESET Press simultaneously for 2 seconds STOVE Figure 14 Damper operation...
Location of the thermostat is very important to obtain the best comfort and efficiency from you ECO-35. The thermostat should be mounted 50 inch from the floor on a wall located 15 to 20 feet from the stove. You should avoid an installation directly in front of the stove to avoid cycling.(See Figure 16)
GLOW, YOU ARE OVERFIRING. Immediately press the YOUR STOVE. If you leave your house and your stove is not connected to a thermostat or a fresh air supply, do not leave it at the maximum setting. If the ambient air in a confined room becomes to hot, the stove may overheat and the thermal protection on the combustion/exhaust motor may be activated, causing the motor to stop.
If so, clean thoroughly. ASH REMOVAL The ECO-35 has an ash bin located below the firebox To remove ashes: Make sure fire is out and the firebox is cool. Open the door and remove the baffle from the firebox. Slide each side of the baffle toward the center to remove(Figure 20).
CLEANING Heat Exchange Tubes – Your ECO-35 stove is designed with a built-in heat exchanger tube cleaner. accumulated ash on the tubes. Slide the cleaning rod back and forth two or three times from front to back (refer to figure 18).
Inspection and Removal – The chimney connector and chimney should be inspected annually or per ton to determine if a creosote or fly ash build- up has occurred. If creosote has accumulated, it should be removed to reduce the risk of a chimney fire. Inspect the system at the stove connection and at the chimney top.
While wearing leather gloves (or any other gloves suitable for handling broken glass), carefully remove any loose pieces of glass from the door frame. Dispose of all broken glass properly. Return the damaged glass to your DROLET Dealer for replacement. It is critical that you replace the glass with a genuine one supplied by your dealer.
Refill the hopper. Remove the burn pot and clean it thoroughly. If the stove is on the low setting, you may need to close the damper all the way. Slide the air supply control toward the minimum setting. Follow all cleaning procedures in the maintenance section of the owner’s manual.
Possible Remedies: Remove the control board and check at the back to see if the F3 fuse is good,; if not replace it with a 5 Amp 250V fuse. Plug the stove back and try to run the unit. Possible Remedies: Using the owner’s manual, locate the L-250 high temperature switch.
AND THEN INSPECT YOUR UNIT. Improper installation, poor maintenance, or a defective or missing component may be causing the stove to overheat. Reset the stove and restart it. Call a technician if you get this code again. *See procedure below to restart the stove.
(Applies to “GLASS SOOTS UP AT A VERY FAST RATE” Only) Possibles Remedies: The stove will restart on the initial setting once it cools off. Note: For a short power failure (less than 5 seconds), the stove will continue to function at the selected speed. Possible Remedies : Remove the control board.
SMOKE SMELL OR SOOT BUILD-UP Because it is a wood-burning device, your ECO-35 may emit a faint wood-burning odor. If this increases beyond normal, or if you notice an unusual soot build-up on walls or furniture, check your exhaust system carefully for leaks. All joints should be properly sealed. Also clean your stove, following instructions in “MAINTENANCE”.
In order to verify the grounding and polarity of the power outlet, the control board sends a low voltage impulse to the stove’s frame. If the polarity is wrong or if the outlet is not properly grounded, you may feel an electric shock when you touch the stove; this low voltage impulse is harmless and connecting your stove to a grounded outlet with the right polarity will keep this from happening and protect your electronics against damages from power surge.
REPLACEMENT PARTS Contact an Authorized DROLET Dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards. ITEM Airflow Pressure Switch Air Switch Hose Auger Motor Burn Pot...
(feet) Let’s imagine an installation consisting of a horizontal vent coming out at the back of the stove on a total distance of 8 feet. This horizontal run is followed by a Tee and a 6-foot vertical rise. This type installation is not acceptable. As you can see, the vent termination is clearly outside the allowed configuration zone on the chart.
Fabriquant de poêle international inc. Stove Builder International Inc. 1700, rue Léon-Harmel, Québec (Québec) G1N 4R9 Phone : (418) 527-3060 E-mail : tech@sbi-international.com Web site : www.drolet.ca CUSTOMER Name Address City Province / State Country Home telephone Work telephone Purchase date...
Paint (peeling), ceramic logs, gaskets, and masonry-like panels *Pictures required Shall your unit or a components be defective, contact immediately your DROLET dealer. Prior to your call make sure you have the following information necessary to your warranty claim treatment: •...