7.6.1.2 Outputs:
Press NEXT again and the screen will display an Output (Op1 = Output 1). Set
the desired input gain level. At this point you can use the BACK/NEXT buttons to
step through each of the parameters for the currently selected output. Press the
GAIN button again to go to the next Output and program all of its parameters.
(The GAIN button will now select only the Output channels; the gain adjustment
screens for the Inputs will not be displayed unless you exit the menu and start
again.) Each Output will have both a number and name displayed. The names
are taken from a default list with labels such as Low, Mid, Highs, Sub, etc.
An alternate method is to program a single parameter for Output 1, such as
DELAY, then press the GAIN button to go to each of the Output channels in turn
and program the delay parameter for that channel. Now select the next param-
eter and program that for each of the outputs in sequence. In some cases this
may make it easier to keep track of the comparative values between outputs.
For simplification, we will follow though programming all the parameters for a
single output.
Set the Gain for Output 1. Range is –40 dB to + 6 dB
7.6.1.3 Polarity:
Set the polarity for Output 1. Switching this will change the phase of the signal
180 degrees.

7.6.1.4 Delay:

Set the Delay time for Output 1. Delay is used to align drivers in a stack that
may be in different vertical planes. Delay range is 0ms to 7ms selectable in .5
ms increments.

7.6.1.5 HPF:

This is part of the crossover function. Sets the "knee" (corner frequency) and
filter slope type for the HiPass Filter (HPF). Frequencies below the selected fre-
quency will be filtered by the selected filter type and slope. Press the PARAM
dial to toggle between these two parameters on the display.

7.6.1.6 LPF:

Set the "knee" (corner frequency) and filter slope type for the LoPass Filter
(LPF). Frequencies above the selected frequency will be filtered by the selected
filter type and slope. Press the PARAM dial to toggle between these two param-
eters on the display.