Kenmore 8804 - 5.8 cu. Ft. Electric Dryer Installation Instructions Manual

Installation instructions
Hide thumbs Also See for 8804 - 5.8 cu. Ft. Electric Dryer:
Table of Contents

Advertisement

Available languages

Available languages

I
I
stallati
structi
®
instrucci
instal
I
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
P/N 134941300 (0708)

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Kenmore 8804 - 5.8 cu. Ft. Electric Dryer

  • Page 1 ® stallati structi instrucci instal Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. P/N 134941300 (0708)
  • Page 2: Table Of Contents

    CONTENTS Pre-lnstallation Requirements ............................Electrical Requirements ..............................Exhaust System Requirements ............................Gas Supply Requirements ............................Location of Your Dryer..............................Rough-In Dimensions ..............................Mobile Home Installation ............................... Unpacking ................................... Reversing Door Swing ..............................Electrical Installation ..............................Grounding Requirements .............................. Electrical Connections--3-wire ............................
  • Page 3: Electrical Requirements

    ELECTRICAL REQUIREMENTS EXHAUST SYSTEM REQUIREMENTS Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible ELECTRICDryer metalduct and approved vent hood which has a swing-out CIRCUIT- Individual 30 amp. branch circuit fused with 30 damper(s) that open when the dryer is in operation. When the amp.
  • Page 4: Gas Supply Requirements

    Connect an inclined or digital manometer between the Do not allow combustible materials (for dryer and the point the exhaust connects to the dryer. example: clothing, draperies/curtains, paper) to come in Set the dryer timer and temperature to air fluff (cool contact with exhaust...
  • Page 5: Location Of Your Dryer

    5. A 1/8 inch (0.32 N.P.T.plugged tapping, accessible for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer. 6. The dryer MUST be disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excess of 1/2 psig (3.45 kPa).
  • Page 6: Rough-In Dimensions

    Dryer Installation Dimensions Free=Standing & Under Counter Electrical supply 48.5" To clear open door on rear of unit (123.19cm) 0 o ,'_,_ # Gas supply pipe on rear of unit 36" "91.44cm) (5. 72 cm) 2.25" 5.0" (12.7cm) Center line height rear, right, left ;_:!::F;;F...
  • Page 7: Mobile Home Installation

    MOBILE HOME INSTALLATION UNPACKING Using the four shipping carton corner posts (two on each I. Dryer MUST be exhausted outside (outdoors, not beneath side), carefully lay the dryer on its left side and remove the the mobile home) using metal ducting that will not support foam shipping base.
  • Page 8: Reversing Door Swing

    Window Door Reversal Instructions Figure Figure 4 1.0pen door and remove four (4) plugs in the door opening 5. Remove two (2) door handle screws and two (2) hole plugs opposite the hinges. Retain all parts for uses later, unless from door.
  • Page 9 11. Reassemble lens to transition ring with holes to install handle on right-hand side of door assembly. For proper fit insure the retention tabs on transition ring are on top of lens Figure 7 8. Remove lens locating screw. (Figure 7) Figure 11 12.
  • Page 10: Electrical Installation

    ELECTRICAL INSTALLATION Canadian ELECTR/CDryer Improper connection of tile equipment grounding ELECTRICDryer conductor can result in a risk of electrical shock. Check with a licensed electrician if you are in doubt as to whether the appliance The following are specific requirements is properly grounded.
  • Page 11: Electrical Connections--3-Wire

    ELECTRICALCONNECTIONS ELECTRICALCONNECTIONS FOR 4- WIRE SYSTEM FOR 3- WIRE SYSTEM USA ELECTR/CDryer USA ELECTRICDryer 1. Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of 1. Remove the screws securing the terminal block access the dryer upper corner.
  • Page 12: Gas Connection

    GAS CONNECTION 7. Place these instructions in a location near the dryer for future reference. 1. Remove the shipping cap from gas pipe at the rear of the NOTE: Awiring diagram is located inside the dryer console or dryer. under the top panel. NOTE: DO NOTconnect the dryer to L.R gas service without REPLACEMENT...
  • Page 13: Espahol

    Tabla de Materias Requerimientos de instalaciOn preliminares ........................Requerimientos el_ctricos ............................... Requerimientos del sistema de escape ......................... 14-16 Requerimientos del suministro de gas..........................Ubicaci6n de su secadora .............................. Dimensiones para la instalaciOn ............................. Instalaci6n en casas m6viles ............................Desembalaje ................................Puerta reversible ................................
  • Page 14: Requerimientos Del Sistema De Escape

    REQUERIMIENTOS DE INS TALA CION Secadora.,Fa GAS PRELIMINARES CIRCUITO- Circuito individual derivado de 15 amp, con fusibles Herramientas y materiales necesarios para la instalaci6n: de 15 amp. de retardo maximo o disyuntor. 1. Destornillador Phillips ALIMENTACION EL_'CTRICA- Corriente alterna, monofasica, 2.
  • Page 15 Risque d'incendie- Une sOcheuse _ linge produit de la charpie Riesgo de explosion. No instale combustible. Si el escape de la secadora no se dirige al exterior, secadora donde se guarda gasolina u otros materiales alqunas pelusas finas seran sopladas hacia el recinto donde se inflamables.
  • Page 16: Requerimientos Del Suministro De Gas

    UBICACION DEL ESCAPE DESPEJESMiNIMOS DE INSTALACION - Todaslas secadorasvienen de fabrica equipadas con escape trasero. Sin embargo, Pulgadas (cm) en las secadoras elOctricas, el escape puede hacerse al lado derecho o izquierdo Parte Parte Parte del gabinete o en la parte inferior de la secadora. En lassecadoras a gas, el escape De/antera Lados Trasera...
  • Page 17: Dimensiones Para La Instalacion

    Dimensiones de la instalaaY)n Fuente ei_ctrica en la parte En el claro abra la puetra 48,5" posterior de la unidad (123.19cm' 0 o _,' _ [...i El tubo de la fuente gas en la parte 36" posterior de la unidad (91.44cm) --i--'-_- 5.0"...
  • Page 18: Instalaci6N En Casas M6Viles

    INSTALAC!ON EN CASAS MOVILES MODEL OS A UTONOMOS CON CONSOLA SUPERIOR DIMENSIONES PARA LA INSTALAC!ON 1. El tubo de escape de la secadora DEBE ser instalado DESEMBALAJE hacia el exterior (El escape debe colocarse en la parte exterior y no debajo de la casa mOvil.) Debe usarse I.
  • Page 19: Puerta Reversible

    Instrucciones para carnbiar la apertura de la Puerta sin Ventana: Figure Figure 4 1. Abra la Puerta y quite los 4 tapones de enfrente a donde 5. Quite dos (2) tornillos de la manija y dos (2) tapones de la se encuentra la bisagra.
  • Page 20 11. Vuelva a montar la lente al anillo de transici6n con los agujeros para instalar la manija en el lade derecho del montaje de la puerta. Para el ajuste apropiado asegure que las lengeetas de retenci6n en el anillo de transici6n estan encima de la lente.
  • Page 21: Instalaci6N El_Ctrica

    INSTALA CION ELECTRICA Para una secadora conectada permanentemente: I. La secadora DEBE ser conectada a un sistema de cableado SecadorasELECTR/CAS metalico permanente, puesto a tierra; o se debe instalar un conductor de puesta atierra de equipojunto con losconductores _F!__ Los siguientes requerimientos del circuito y conectarse al borne de puesta a tierra del equipo especificos para el funcionamiento...
  • Page 22: Conexiones El_Ctricas - Trifilares

    CONEXIONES ELECTRICAS PARA CONEXIONES ELECTRICAS PARA UN SISTEMA TETRAFILAR UN SISTEMA TRIFILAR Secadoras ELECTR/CASNo Canadienses Secadoras EL_-CTR/CASNo Canadienses 1. Saque los tornillos que sujetan la cubierta de acceso al las Saque los tornillos que sujetan la cubierta de acceso del tablero terminales y el soporte de montaje del anclaje del cordon, de term inalesy el soporte de montaje del anclaje de cable situado situado en la esquina superior de la parte trasera de la...
  • Page 23: Piezas De Recambio

    CONEXION DEL GAS 6. Si su secadora no funciona, consulte la seccion "Lista de Control de Averias" que se encuentra en su Manual del I. Saque la tapa de embarque de la tuberia de gas de la secadora Usuario, antes de Ilamar para obtener servicio. situada en la parte trasera.
  • Page 24 Your Home For repair- in your home - of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories owner's manuals that you need to do-it-yourself. For Sears professional installation of home appliances...

This manual is also suitable for:

9804 - 5.8 cu. ft. gas dryer

Table of Contents