AIR CLEANER
If the air cleaner element has become
clogged with dust, intake resistance will
increase with a resultant decrease in power
output and an increase in fuel consumption.
If riding under severe conditions must be
cleaned or replaced more frequently than
maintenance schedule. Check and clean
the air cleaner element periodically accord-
ing to the following procedure.
CAUTION
If the air cleaner element is polluted, will
occur to starting go out, output
insuffiency, combustion efficiency
decline, and sooty smoke(black smoke).
This appearence is occurred at first to
clean the air cleaner element and con-
firm.
1. Take out the air cleaner cap by disas-
sembling 7 screws.
2. Take off the air cleaner element.
3. Fill a washing pan of a proper size with
nonflammable cleaning solvent �.
Immerse the element in the cleaning sol-
vent and wash it clean.
4. Squeeze the cleaning solvent out of the
washed element by pressing it between
the palms of both hands : do not twist or
wring the element or it will develop tears.
5. Immerse the element in HYOSUNG gen-
uine oil � and squeeze the oil out of the
element leaving it slightly wet with oil.
6. Assemble the air cleaner element.
46