System Overview
Zones and Partitions
• The system sensing devices have been assigned to various "zones," which are
specific areas of protection (e.g., front door, kitchen window, etc.).
• Zone numbers are displayed at the keypad when an alarm or trouble condition
occurs on a sensor.
• Partitions (VISTA-20P Series) provide two independent areas of protection, with
each partition containing a group of zones that can be armed and disarmed
without affecting other zones or users.
• Partitioned systems (VISTA-20P Series) can include a common zone area, which
is an area shared by users of both partitions (such as a lobby in a building).
Arming, Step-Arming and Disarming Burglary Protection
• The system must be armed before the burglary protection can sense intrusions.
• To arm your system, enter your user code followed by the desired arming key.
• If programmed, you can press the [#] key in place of your user code when arming
the system (e.g., instead of entering your 4-digit user code + [3-STAY] to arm the
system in STAY mode, you can press [#] + [3-STAY]).
• You can also use the step-arming feature if programmed, to arm the system. This
is a function key that allows you to arm the system in one of three modes by
simply pressing the key repeatedly.
• To disarm the system, enter your user code then press the [OFF] key.
Alarms
• When an alarm occurs, both the keypad and external sounders sound, and the
keypad displays the zone(s) causing the alarm.
• If your system is connected to a Central Monitoring Station, an alarm message is
also sent. (Delayed Reporting Note: Message reporting is delayed 30 seconds
by default to reduce false alarms. If desired, this delay can be removed or can be
increased to 45 seconds. See your installer if you want the delay time changed.)
• To stop the alarm sounding, simply disarm the system.
Memory of Alarm
• When an alarm condition occurs, the keypad displays the number(s) of the
zone(s) that caused the problem, and displays the type of alarm.
• The message remains displayed even after disarming the system, but can be
cleared with another "off" sequence.
Phone Access
• If included, a phone module permits you to access the system via a touch-tone
phone, either on-premises or by call-in when away.
• When you call in, the phone module announces system status over the telephone,
and you can arm/disarm the system and perform most function commands
remotely using the telephone keys.
• Complete information for using these features is provided with the voice module.