2. Isolate the SCSI subsystem from the controller by disconnecting all hard disk
3. If original ISPR code is still present after disconnecting all hard disk drive cables

ServeRAID error codes

In the following error codes, x can be any number or letter.
Error code/symptom
1xxx (Microcode checksum error)
2xxx (Code DRAM error)
3000-31XX (Code DRAM error)
3200 (Code DRAM error)
3300 (ServeRAID-5i only)
3E20 (ServeRAID-5i only)
drive cables attached to the suspect adapter, and restart the computer.
CAUTION:
Do not press F5. Doing so will change the configuration of the server.
If ISPR code is EF10 after disconnecting cables, complete the following steps
until the error is eliminated:
a.
Identify which channel is causing the error by reconnecting cables one at a
time and restarting the computer until the error returns.
b. Check the termination of the channel that was identified in step 2a.
Note: SCSI channel termination details, if any, appear elsewhere in this
publication.
c. Disconnect one drive at a time attached to the channel identified in step 2a
and reboot each time to determine which drive is causing the problem.
d. Replace the hard disk drive cable attached to the channel identified in step
2a.
e. Replace the backplane attached to the channel identified in step 2a.
and restarting the computer, perform the following actions until the error is no
longer present:
v Reseat the controller
v Replace the controller
FRU/action
1. ServeRAID controller
1. Install download jumpers, flash latest level BIOS code
and firmware for controller. Remove jumpers.
2. ServeRAID controller.
1. Install download jumpers, flash latest level BIOS code
and firmware for controller. Remove jumpers.
2. ServeRAID controller.
1. Install download jumpers, flash latest level BIOS code
and firmware for controller. Remove jumpers.
2. ServeRAID controller.
1. Install ServeRAID-5i controller in an extended PCI
option slot. See the documentation that came with the
server for more information.
1. Remove the ServeRAID-5i controller from its slot and
install it in the proper PCI option slot.
2. Verify that the ServeRAID-5i controller is supported in
this server.
3. ServeRAID-5i controller.
4. System board.
95