An extension user can chain dial with One-Touch Keys. For example, a user can
store the number for a company Automated Attendant in key 1 and employee
extension numbers in keys 2~5. The user can press key 1 to call the company, then
one of keys 2~5 to ring the employee to whom they want to speak.
An extension user or system administrator can optionally store a Flash command
under a One-Touch key. This is helpful for One-Touch Keys used as Station Speed
Dial bins. The stored Flash may be helpful to access features of the connected Telco,
PBX or Centrex.
Operator
When an extension user dials 0, calls are routed to a main system Operator. The
Operator can answer and route outside calls or locate employees using the Page
feature.
A maximum of eight Operators is available.
(OPX) Off-Premise Extension
Off-Premise Extension allows a single line telephone, located remotely from the main
installation site, to access the system features with the same abilities as an
on-premise single line telephone.
Paging, External
With External Paging, a user can broadcast announcements over paging equipment
connected to external Paging zones. When a user pages one of these external zones,
the system broadcasts the announcement over the speakers. Like Internal Paging,
External Paging allows a user to locate another employee or make an announcement
without calling each extension individually.
The UNIVERGE SV8100 system allows up to eight External Paging zones, or a
common zone output provided by the CPU (Speaker 9). All other speakers (1~8)
require a port on a PGD(2)-U10 ADP, with a maximum of two external paging circuits
per module. You must have four PGD(2)-U10 ADPs to get the eight external zones.
Each external zone has an associated relay contact. When a user pages to a zone,
the corresponding contact activates (closes). This provides for Paging amplifier
control.
Combined Paging
Use Combined Paging when you want to simultaneously Page into an internal and
corresponding external zone. For example, you can Page your company warehouse
and outside loading dock at the same time. Combined Paging is available for zones
1~8 and All Call. You can program a Function Key as a Combined Paging key. Using
the External Page Function Key, when an All Call External Page Function Key is
programmed, it includes both the external zones and the assigned internal zone(s). If
the internal page zone is busy or there are no extensions in a page group, the
announcement is made on the external zones only.