Refrigerating Cycle - LG HB1003R Service Manual

Service manual
Table of Contents

Advertisement

Disassembly
5. MOTOR
1. Remove the cabinet.
2. Remove the turbo fan.
3. Remove the fan.
4. Remove the 4 screws which fasten the motor from
the air guide. (See Figure 28)
5. Remove the motor.
6. Re-install the components by referring to the
removal procedure, above.(See Figure 28)

Refrigerating Cycle

1. CONDENSER
CAUTION:
Discharge the refrigerant system using a Freon
to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon
the valve in place after servicing the system.
1. Remove the cabinet.
2. Remove the 5 screws which fasten the
brace.
3. Remove the 5 screws which fasten the condenser
and shroud.
4. After discharging the refrigerant completely,
unbraze the interconnecting tube at the condenser
connections.
5. Remove the condenser.
6. Re-install the components by referring to notes.
(See Figure 29)
2. EVAPORATOR
1. Remove the control box.
2. Remove the air guide upper.
3. Remove the 2 screws which fasten the evaporator.
4. Move the evaporator sideways carefully.
5. After discharging the refrigerant completely,
unbraze the interconnecting tube at the evaporator
connections.
6. Remove the evaporator.
7. Re-install the components by referring to notes.
(See Figure 30)
18 Room Air Conditioner
Figure 28
Recovery System. If there is no valve
TM
Figure 29
Figure 30
. Leave
TM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents