Alternate Arming Methods; Away Arming; Stay Arming; Arming Without Entry Delay - DSC PC1555 - MANUAL 2 Instruction Manual

Hide thumbs Also See for PC1555 - MANUAL 2:
Table of Contents

Advertisement

Alternate Arming Methods

Away Arming

Arming the system in the Away mode will have all interior zones and perimeter zones active. If motion
is detected in the interior zones, or if one of the perimeter zones is violated, the alarm sequence will
begin.
To arm in the Away mode, enter your access code and exit the premises through a designated Exit/
Entry door. The system will recognise that occupants have left the premises. Once the exit delay
expires, the system will be fully armed.
You can restart the exit delay once by pressing the Away button before the exit delay expires.
Audible Exit Fault
In an attempt to reduce false alarms, the Audible Exit Fault is designed to notify you of an improper
exit when arming the system in the Away mode. In the event that you fail to exit the premises during
the allotted exit delay period, or if you do not securely close the Exit/Entry door, the system will notify
you that it was improperly armed in two ways: the keypad will emit one continuous beep and the bell
or siren will sound. If this occurs, you must re-enter the premises, enter your access code to disarm
the system, and then follow the arming procedure again, making sure to exit the premises in the
proper fashion.

Stay Arming

This feature, if enabled by your installer, will allow you to arm the perimeter zones while leaving the
interior zones inactive so that you can remain on the premises while the system is armed.
When you enter your security code to arm the system and do not exit the premises through a
designated Exit/Entry door, the system will arm in the Stay mode, automatically bypassing the interior
zones.
The interior zones can be reactivated at any time by entering [ ][1] at any keypad. If you reactivate
the interior zones, be sure to only inhabit areas not covered by motion detectors. To access areas
protected by motion sensors, you must enter your security code and disarm the system.

Arming Without Entry Delay

If you wish to arm your system without the entry delay, enter [ ][9] then your access code. The Armed
light will flash as a reminder that the system is armed and has no entry delay. An entry through any
zone programmed as a delay zone will create an instant alarm.
Quick Arm
When the Quick Arm feature is enabled, the system may be armed by simply pressing [ ][0] instead
of your access code. Please note that pressing [ ][0] will only allow you to arm the system; to disarm,
you must enter a valid access code. Your installer will inform you if the Quick Arm feature has been
enabled on your system.
Quick Exit
When the Quick Exit feature is enabled, pressing [ ][0] while the system is armed will provide a two
minute window for you to exit the premises. During this time, you may only open and close the
designated Entry/Exit door once. Once the door is closed, the panel will end the two minute quick
exit delay. If the door is opened again, or if the door is not closed after two minutes, or if another zone
is opened, the panel will begin the entry delay. Your installer will inform you if the Quick Exit feature has
been enabled on your system.
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Classic pc1555

Table of Contents