System Light (PC1555RKZOnly):
If the System light is ON, one or more of these
conditions could be present on the system:
System Busy
System Troubles (See "Viewing Trouble Conditions" on
page 11).
Alarm Memory (See "Disarming the System" on page 6).
Zone Bypassing (See "Zone Bypassing" on page 11).
Programming The System light will flash when you
are programming access codes, or performing other
programming functions. If someone is programming
at another keypad, the System light will turn ON to
indicate that the system is busy.
NOTE: If you have a PC1555RKZ keypad, the
System light acts as a Trouble, Memory,
Programming and Bypass indicator. Unlike the
other keypads, these conditions will only be
represented by the System light. Please keep this in
mind when reading other functions in this manual.
Display Lights (All Keypads)
Ready Light
If the Ready light is ON, the system is ready for arming. The
system cannot be armed unless the Ready light is ON (see
"Arming the System" on page 4).
Armed Light
If the Armed light is ON, the system has been armed
successfully.
Trouble or System Light
If the Trouble light is ON, see "Viewing Trouble
Conditions" on page 11.
8
Emergency Keys (All Keypads)
PC5508Z / LCD5500Z:
Press both * Keys for two seconds to send a FIRE
transmission.
Press both
* Keys for two seconds to send an
AUXILIARY transmission.
Press both
* Keys for two seconds to send a
PANIC transmission.
PC1555RKZ:
Press the [F]* key for two seconds to send a FIRE
transmission.
Press the [A]* key for two seconds to send an
AUXILIARY transmission.
Press the [P]* key for two seconds to send a PANIC
transmission.
* IMPORTANT NOTE (All Keypads): The Fire,
Auxiliary and Panic keys will NOT function unless
programmed by the installer. If these keys are in
service and the installer has enabled audible
feedback, holding down the key for two seconds will
cause the keypad sounder to beep indicating that the
input has been accepted and transmission is
underway.
NOTE: In the U.S.A. the [A] and
programmed to be used for non-medical
emergencies only, as per UL requirements.
Display Lights (PC5508Z, PC5516Z, PC5532Z
Keypads)
Memory Light
Upon disarming, if an alarm has occurred while the
system was armed, the Memory light will turn ON
(See "Disarming the System" on page 6).
Bypass Light
If the Bypass light is ON, one or more zones are
bypassed (See "Zone Bypassing" on page 11).
Fire Light
If the Fire light is ON, a fire alarm has occurred (See
"Fire Alarm Operation" on page 14).
Program Light
The Program light will flash when you are
programming access codes, or performing other
programming functions. If someone is programming
at another keypad, the Program light will turn ON to
indicate that the system is busy.