A) COMMAND is receivable also during transmission of EVENT.
B) The RESPONSE should be sent as opposed to the request command by all the commands with which an EVENT exists , not need to
the another request commands(ex. SV command).
C) The PARAMETER (with COMMAND and RESPONSE, EVENT) of minimum level of MASTER VOLUME defines "99".
D) If the MASTER VOLUME & CHANNEL VOLUME set with 0.5dB step, the PARAMETER (with COMMAND and RESPONSE, EVENT) defines three
ASCII characters as bellows.
Ex.

MASTER VOLUME =

* At the **.0dB step, only uses two ASCII characters as PARAMETER, same as usual.
K) Four seconds later, please transmit the next COMMAND after transmitting a power on COMMAND(PW00ON).
0dB
:
SV90<CR>
-0.5dB :
SV895<CR>
-1.0dB :
SV89<CR>
|
|
-89.5dB :
SV005<CR>
-90.0dB :
SV00<CR>
---.-dB :
SV99<CR>