Others
A) COMMAND is receivable also during transmission of EVENT.
B) The RESPONSE should be sent as opposed to the request command by all the commands with which an EVENT exists , not need to
the another request commands(ex. SV command).
C) The PARAMETER (with COMMAND and RESPONSE, EVENT) of minimum level of MASTER VOLUME defines "99".
D) If the MASTER VOLUME & CHANNEL VOLUME set with 0.5dB step, the PARAMETER (with COMMAND and RESPONSE, EVENT) defines three
ASCII characters as bellows.
Ex.
MASTER VOLUME =
* At the **.0dB step, only uses two ASCII characters as PARAMETER, same as usual.
K) Four seconds later, please transmit the next COMMAND after transmitting a power on COMMAND(PW00ON).
0dB
:
SV90<CR>
-0.5dB :
SV895<CR>
-1.0dB :
SV89<CR>
|
|
-89.5dB :
SV005<CR>
-90.0dB :
SV00<CR>
---.-dB :
SV99<CR>
- 6 -