Page 1
TM-90R/TM-2000 HUMIDISTAT INSTALLATION INSTRUCTIONS CAUTION: DISCONNECT THE TM-90R/TM-2000 TRANSFORMER FROM THE RECEPTACLE AND SWITCH "OFF" THE FURNACE ELECTRICAL SUPPLY PRIOR TO INSTALLING THIS HUMIDISTAT. 1. Remove Humidity Control from front side of Base Plate and re- attach to back side of Base Plate. The Adjustment Knob must protrude through the hole in the Base Plate.
Page 2
5. Refer to the Wiring Diagram and attach the wires to the Humidity Control terminals #2 and #3, both Transformer terminals and both TM-90R/TM-2000 terminals, as indicated. The Wiring Diagram shows the proper wire termination required for each connection. CAUTION: All wiring should conform to The National Electrical Code, NEC, and any applicable local codes.
Page 4
6. Attach the Foam Mounting Gasket to the Return Air Plenum around the opening which was previously cut. Secure the Base Plate to the furnace plenum using the two screws supplied. Be sure that the wires are placed through the wiring slot.
Page 5
NOTE: The Humidity level indications on the Humidistat Cover are for reference only. It may be necessary to adjust the Knob to a higher or lower setting based upon the actual humidity level within the home. P/N 46259500...