Download Print this page

Field Controls 46244900 Manual

Thermocouple junction block

Advertisement

Quick Links

THERMOCOUPLE JUNCTION BLOCK
This device is used to attach spill switches to a 30 millivolt water heater. It is designed to be used with
models GSK SERIES spill switches, TSP SERIES spill switch or SSK SERIES spill switch kits for
connecting flue gas sensing spillage switches to 30 millivolt gas valves.
Model: TCA-1
R
EQUIRED ACCESSORIES
2-GSK series spill switches
6 ft. of 12 ga. two (2) wire stranded (preferably) conductor.
1-TSP series spill switch
6 ft. of 12 ga. two (2) wire stranded (preferably) conductor.
1-SSK series spill switch kit
Includes two (2) spill switches and 12 ga wire.
OR
OR

Advertisement

loading

Summary of Contents for Field Controls 46244900

  • Page 1 THERMOCOUPLE JUNCTION BLOCK Model: TCA-1 This device is used to attach spill switches to a 30 millivolt water heater. It is designed to be used with models GSK SERIES spill switches, TSP SERIES spill switch or SSK SERIES spill switch kits for connecting flue gas sensing spillage switches to 30 millivolt gas valves.
  • Page 2 CAUTION: If for any reason the system has shut down during normal operation, the cause of the system failure should be investigated and corrected before resetting the safety switch and relighting the pilot. Figure 3 Page 2 P/N 46244900 Rev A 12/00...

This manual is also suitable for: