5) Wait for a while. Then, "OK" appears on the PC.
6) Remove the USB cable. At this moment, be careful not to touch the POWER button.
By removing the USB cable, "OK" on the PC disappears.
7) The unit is automatically started up.
[T&D Execution]
8) Execute T&D. For procedures, refer to the function test of unit's board.
<Function test of unit's board>
[Preparation] (Equipment required)
Wired remote controller
AC adaptor and AC cord
AV cable (Only for model equipped with TV output function)
Display with composite input (Only for model equipped with TV output function)
[Inspection]
a) Connect the AC adaptor to the unit. The OS stored on the HDD starts up.
b) Using the buttons on the front of unit, select T&D from the menu displayed on the LCD.
c) When T&D is selected, the menu to select an item to be tested appears on the LCD.
Select [function test (MP)].
d) According to the instruction displayed on the LCD, operate (Press the button.).
e) When operating according to the instruction, the LCD becomes entirely black/white, check visually.
f) When "Connect Controller" appears, connect the remote controller to the Headphone jack and operate the
button on the remote controller according to the instruction displayed on the LCD.
g) When "Disconnect Controller" appears, plug out the remote controller.
h) If the unit has no TV out, jump to step k). If the unit has the TV out, "Connect TV out" appears, When
this message appears, connect the AV cable to the Headphone jack.
(Depending on plugging out the remote controller, "Disconnect TV out" may not appears and the LCD
display may become "OFF. But, this is not a trouble. Irrespective of this, connect the AV cable to the
Headphone jack and proceed to the next step.)
i) Confirm that the test pattern and "Push OK" appear on the display to which the AV cable is connected.
j) Press "OK" button. Then, the test pattern disappears.
k) "PASS" appears on the LCD. ("When "PASS" appears, the inspection is finished.)
l) Press "Power" button to suspend the unit, and then plug out the AC adaptor.
[Note]
Before conducting the inspection, the specified T&D software must be installed.