• Allocation of pins of the Brown 12-way MQS connector of the main harness.
1
7
2
8
3
9
4
10
5
11
6
12
1
7
2
8
3
9
4
10
5
11
6
12
• Allocation of pins of the Blue 12-way MQS connector of the passenger
compartment.
1
7
2
8
3
9
4
10
5
11
6
12
MULTIPLEXED BSI - XSARA PICASSO AND XSARA – PART 1
© AUTOMOBILES CITROËN Toute reproduction ou traduction même partielle sans l'autorisation écrite d'AUTOMOBILES CITROËN est interdite et constitue une contrefaçon
21
1 - Input: On board ECU scroll request
2 - Input: Navigation recall last message request
3 - For supplier use
4 - Output: Headlamp washer relay control
Output: Sidelamp relay control (timed illumination)
5 - Output: Air conditioning compressor authorisation request
to engine ECU
6 - Input: Air conditioning compressor authorisation through
engine ECU
7 - Analogue earth
8 - Input: Evaporator temperature information
9 - Input: Fuel flow information through engine ECU
10 - Input: Coolant temperature information through thermistor
(analogue)
11 - Input: Refrigerant pressure safety information
12 - Input: Air conditioning request
1 - Output: Ultra sound module supply
2 - Input: Bonnet switch
3 - Input/Output: Siren serial connection
4 - Output:
Close
(dead)locking
5 - Input: Alarm request through ultrasound module
6 - Input: Volumetric suppression request button
7 - 12 - Spare
electric
windows