Axcess Programming
PROGRAM Port Commands (Cont.)
SET BASE DEVICE
NUMBER
SET DATE
SET TIME
SHOW DEVICE
SHOW INPUT OFF
SHOW INPUT ON
SLOT
SYSTEM RESET
TIME
VERSION
20
Master and
Sets the AXlink base device number on the controller's RS-232 port
Slave
1. Subsequent ports on the controller are incrementally set. If the
device number is 1, the controller becomes an AXlink bus master,
and if the device number is set to 2-xxx, the controller becomes a
slave.
Syntax:
SET BASE DEVICE NUMBER <Device>
Variables:
Device = 1 - 238
Master
Changes the date in the controller.
Syntax:
SET DATE
Master
Changes the time in the controller.
Syntax:
SET TIME
Master
Displays a list of all devices present on the AXlink bus.
Syntax:
SHOW DEVICE
Master
Sets Show Input mode off.
Syntax:
SHOW INPUT OFF
Master
Sets Show Input mode on.
Syntax:
SHOW INPUT ON
Master
The active controller returns its slot number.
Syntax:
SLOT
Master
The controller stops communication on AXlink for 2 seconds and
then restarts. The system program then restarts according to the
Define_Start section.
Syntax:
SYSTEM RESET
Master
The controller returns the time in its internal clock.
Syntax:
TIME
Master and
Displays current software version of the controllers.
Slave
Syntax:
VERSION