CMOS checksum error - Defaults loaded
Checksum of CMOS is incorrect, so the system loads the default equipment
configuration. A checksum error may indicate that CMOS has become corrupt.
This error may have been caused by a weak battery. Check the battery and
replace if necessary.
CPU at nnnn
Displays the running speed of the CPU.
Display switch is set incorrectly.
The display switch on the motherboard can be set to either monochrome or
color. This message indicates the switch is set to a different setting than
indicated in Setup. Determine which setting is correct, and then either turn off
the system and change the jumper, or enter Setup and change the VIDEO
selection.
Press ESC to skip memory test
The user may press Esc to skip the full memory test.
Floppy disk(s) fail
Cannot find or initialize the floppy drive controller or the drive. Make sure the
controller is installed correctly. If no floppy drives are installed, be sure the
Diskette Drive selection in Setup is set to NONE or AUTO.
HARD DISK initializing Please wait a moment...
Some hard drives require extra time to initialize.
HARD DISK INSTALL FAILURE
Cannot find or initialize the hard drive controller or the drive. Make sure the
controller is installed correctly. If no hard drives are installed, be sure the Hard
Drive selection in Setup is set to NONE.
Hard disk(s) diagnosis fail
The system may run specific disk diagnostic routines. This message appears if
one or more hard disks return an error when the diagnostics run.
Keyboard error or no keyboard present
The keyboard cannot initialize. Make sure the keyboard is attached correctly
and no keys were pressed during POST. To purposely configure the system
without a keyboard, set the error halt condition in Setup to HALT ON ALL,
BUT KEYBOARD. The BIOS then ignores the missing keyboard during POST.