Figure 1. Installing The Barrel Standoff; Figure 2. Installing Intel ® Integrated Raid Module Rms2Af0X0 - Intel AXXRMS2AF080 Hardware User's Manual

Integrated raid module
Table of Contents

Advertisement

5. Press down gently but firmly to ensure that the card is properly seated in the
connectors, and then insert the three pin standoffs into the barrel standoffs
respectively ( see
6. Connect the SAS/SATA cables from the backplane (or hard drives) to the RAID
module (see
Right-angle end or Vertical end of the SAS/SATA cable to the SAS connectors of
the controller, see your server/workstation board or chassis documentation. Make
sure the cables are properly connected to the controller.
Note: System throughput problems can occur if non-standard SAS cables are used.
8

Figure 1. Installing the Barrel Standoff

Figure
Figure 2. Installing Intel
Figure
3). For information regarding connecting the recommended
To minimize the potential for problems:
Use cables no longer than ten meters for SAS and one meter for SATA. It is
better to use the shortest possible cables. The cable length should be reduced
by about one foot (.33 meters) if using a backplane.
You may connect one device per SATA/SAS cable either as a device or as an
expander.
Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User's Guide
2).
®
Integrated RAID Module RMS2AF0x0
AF003487
AF003489

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rms2af040Axxrms2af040Rms2af080

Table of Contents