Comfort Glow CCL3018NR Owner's Operation And Installation Manual page 15

Unvented (vent-free) gas log heater
Hide thumbs Also See for CCL3018NR:
Table of Contents

Advertisement

INSTALLATION
Continued
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Figure 15).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve for
propane/LP gas or opening main gas valve lo-
cated on or near gas meter for natural gas, or
using compressed air.
3. Check all joints from propane/LP supply tank
to equipment shutoff valve for propane/LP gas
(see Figure 16) or from gas meter to equip-
ment shutoff valve for natural gas (see Figure
17). Apply noncorrosive leak detection fluid
to gas joints. Bubbles forming show a leak.
4. Correct all leaks at once.
PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 15).
2. Open propane/LP supply tank valve or main
gas valve located on or near gas meter for
natural gas.
3. Make sure control knob of heater is in the OFF
position.
4. Check all joints from propane/LP supply tank
to equipment shutoff valve for propane/LP gas
(see Figure 16) or from gas meter to equip-
ment shutoff valve for natural gas (see Figure
17). Apply noncorrosive leak detection fluid
to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, page 19).
Check all other internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appli-
ance, page 20).
Equipment
Shutoff
Valve
Figure 15 - Equipment Shutoff Valve
111161-01D
Propane/LP
Tank
Gas Meter
INSTALLING REMOTE RECEIVER
UNIT
1. Disconnect switch wires from the control
2. Remove phillips head screws and heat shield.
3. Remove switch plate (see Figure 18). Discard
Open
O
Screws
POSI
Closed
PO
Figure 18 - Switch Plate and Wiring
Harness (Switch Plate and Orientation
www.desatech.com
Equipment
Shutoff Valve
Thermostat Gas Valve or
Control Valve Location
Figure 16 - Checking Gas Joints
Equipment
Shutoff Valve
Thermostat Gas Valve or
Control Valve Location
Figure 17 - Checking Gas Joints
valve.
after removing.
Front
Wires
May Vary Depending On Model)
Back
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save Article as PDF