Continued
6.
Carefully supervise young children when they are in the room
with stove.
7.
Do not modify the burner or stove under any circumstances. Any
parts removed for servicing must be replaced prior to operating
stove or burner system.
8.
Turn burner system off and let cool before servicing, install-
ing, or repairing. Only a qualified service person should in-
stall, service, or repair the stove or burner system. Have burner
system inspected annually by a qualified service person.
9.
You must keep control compartments, burners, and circulat-
ing air passages clean. More frequent cleaning may be needed
due to excessive lint and dust from carpeting, bedding mate-
rial, pet hair, etc. Turn off the gas valve and pilot light before
cleaning stove or burner system.
10. Have venting system inspected annually by a qualified service
person. If needed, have venting system cleaned or repaired.
See Cleaning and Maintenance, page 29.
11. Keep the area around your stove clear of combustible materi-
als, gasoline, and other flammable vapor and liquids. Do not
run burner system where these are used or stored. Do not place
items such as clothing or decorations on or around stove.
12. Do not use this stove to cook food or burn paper or other objects.
13. Never place anything on top of stove.
14. Do not use any solid fuels (wood, coal, paper, cardboard, etc.)
in this stove. Use only the gas type indicated on burner system
nameplate.
15. This appliance, when installed, must be electrically grounded
in accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, or the Ca-
nadian Electrical Code, CSA C22.1.
16. Do not obstruct the flow of combustion and ventilation air in
any way. Provide adequate clearances around air openings into
the combustion chamber along with adequate accessibility
clearance for servicing and proper operation.
17. Do not install stove directly on carpeting, vinyl tile, or any com-
bustible material other than wood. The stove must set on a metal
or wood panel extending the full width and depth of the stove.
18. Do not use stove or burner system if any part has been ex-
posed to or under water. Immediately call a qualified service
person to arrange for replacement of the unit.
19. Do not operate burner system if any log is broken.
20. Do not use a blower insert, heat exchanger insert, or other ac-
cessory not approved for use with this stove.
21. Do not operate burner system with glass door removed, cracked,
or broken.
22. Provide adequate clearances to air openings.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
112126-01B
SAFETY INFORMATION

PRODUCT IDENTIFICATION

PRODUCT IDENTIFICATION
Cast Iron
Stove Body
Log Set
Piezo Ignitor
Vent
Opening
Rear
Cover
Pilot
Assy
Blower with
Adjustment
Knob (Optional
Installation)
Glowing
Embers
Figure 1 - DESA Direct-Vent Burner System Shown Installed in
Approved Cast Iron Stove Body (Oxford™ Model Shown)
3 3
LO
IN
OUT
Control Valve
Cast Iron
Stove Body
Stove
Front
Burner
Glass
Door Assy
Lava Rock
Grate Assembly