Desa VM42P Owner's Operation And Installation Manual page 12

B-vent decorative gas fireplace
Table of Contents

Advertisement

INSTALLATION
Continued
OPTIONAL WIRELESS HAND-HELD
REMOTE CONTROL INSTALLATION
Note: If using optional wireless hand-held remote
control, the wall switch is no longer operational.
Installing Receiver
1. Remove the front refractory access panel by
lifting up and angling out of the firebox opening
(see Figure 13, page 11) to expose controls.
2. Disconnect wall switch wires from TH
and TH/TP terminals on control valve (see
Figure 14).
3. Install remote receiver unit onto mounting
bracket using the two plastic mounting clips
(see Figure 15).
4. Connect wires to control circuit. Connect
white wire to terminal marked TH/TP on
control valve. Connect red wire to male blade
connector provided at open end of safety cir-
cuit wiring (see Wiring Diagram, page 22).
5. Locate the battery clip mounted on the back
of the receiver (see Figure 16).
6. Slide 9-volt battery (not included) through the
clip. Note: Only use alkaline battery.
7. Attach the terminal wires to the battery (see
Figure 16).
8. Replace refractory brick access panel.
Note: If any of the original wire as supplied must
be replaced, use 18 AWG TYPE CL2 (UL) 105 C
(25 ft. length MAXIMUM) or equivalent.
Figure 14 - Wall Switch Wiring Diagram
12
To Safety Circuit
To Thermopile
www.desatech.com
Receiver
Figure 15 - Installing Remote Receiver
(Shown from Rear of Mounting Bracket)
Route Millivolt
Wires (Supplied)
Through Gas Line
Conduit Sleeve
Plastic
Mounting
Clips
Mounting Bracket
Wall Switch
(Supplied)
(Back View)
108795-01N