If Acronis License Server is unavailable, Acronis Backup & Recovery 10 will continue working
with full functionality for the number of days specified in
Maximum Time Without License Server, as counted from the moment of installation or from
the last successful check.
License Server Connection Retry Interval (in hours)
Description: Specifies the interval, in hours, between connection attempts when Acronis
License Server is unavailable.
Possible values: any integer number between 0 and 24
Default value: 1
If, during a check for the license key (see License Check Interval earlier in this topic), Acronis
Backup & Recovery 10 Agent could not connect to the license server, it will try to reconnect
once in the number of hours given by License Server Connection Retry Interval.
If the value is 0, no reconnection attempts will be performed; the agent will only check for
the license as determined by License Check Interval.
License Server Address
Description: Specifies the network name or IP address of Acronis License Server.
Possible values: Any string 0 to 32765 characters long
Default value: Empty string
Log Cleanup Rules
Specifies how to clean up the agent log.
This parameter has the following settings:
Max Size
Description: Specifies the maximum size of the agent log folder, in kilobytes.
Possible values: Any integer number between 0 and 2147483647
Default value: 1048576 (that is, 1 GB)
Percentage To Keep
Description: Specifies the percentage of the maximum log size to keep on cleanup.
Possible values: Any integer number between 0 and 100
Default value: 95
For details on how the agent log is cleaned up, see Log cleanup rules (p. 98).
Windows Event Log
Specifies when to record Acronis Backup & Recovery 10 Agent's events into the Application event
log in Windows.
This parameter has two settings:
Trace State
Description: Specifies whether to record the agent's events into the event log.
Possible values: True or False
Default value: False
Trace Level
Description: Specifies the minimum level of severity of events to be recorded into the event
log. Only events of levels greater than or equal to the value in Trace Level will be recorded.
Possible values: 0 (Internal event), 1 (Debugging information), 2 (Information), 3 (Warning), 4
(Error), or 5 (Critical error)