Zoned Storage-With Two C-Class Enclosures - HP 2000sa Deployment Manual

Hp direct-connect external sas storage for hp bladesystem solutions deployment guide
Hide thumbs Also See for 2000sa:
Table of Contents

Advertisement

Zoned storage—with two c-Class enclosures
This example illustrates cabling from two BladeSystem c-Class enclosures to one MDS600 storage
enclosure. In this configuration, note the following:
This example shows a dual-domain MDS600 with wide-port cabling. Dual-domain standard
cabling and single-domain devices are also supported.
96
Deployment examples
Devices and quantities
MDS600 storage enclosures: 1
c7000 enclosures: 2
3Gb SAS BL Switches: 4 (2 in each c-Class
enclosure
Server blade types: half-height and full-height
Connection details
Top c7000, Switch in interconnect bay 5:
◦ Port 1: to MDS600 drawer 2, primary I/O
module, port 1
◦ Port 2: to MDS600 drawer 2, primary I/O
module, port 2
Top c7000, Switch in interconnect bay 6:
◦ Port 1: to MDS600 drawer 2, secondary
I/O module, port 1
◦ Port 2: to MDS600 drawer 2, secondary
I/O module, port 2
Bottom c7000, Switch in interconnect bay 5:
◦ Port 1: to MDS600 drawer 1, primary I/O
module, port 1
◦ Port 2: to MDS600 drawer 1, primary I/O
module, port 2
Top c7000, Switch in interconnect bay 6:
◦ Port 1: to MDS600 drawer 1, secondary
I/O module, port 1
◦ Port 2: to MDS600 drawer 1, secondary
I/O module, port 2
Notes
When connecting one MDS600 storage
enclosure to two BladeSystem c-Class
enclosures, each c-Class enclosure has
exclusive access to one of the MDS600
storage drawers.
As shown in this illustration, server bays 1–8
in the top c7000 may access MDS600
drawer 2 and server bays 1–8 in the bottom
c7000 may access MDS600 drawer 1. For
more information, see
"HP 3Gb SAS BL
Switch port information" (page
83).

Advertisement

Table of Contents
loading