Zoning Information; Types Of Zone Groups; Key Zoning Configuration Steps - HP 2000sa Deployment Manual

Hp direct-connect external sas storage for hp bladesystem solutions deployment guide
Hide thumbs Also See for 2000sa:
Table of Contents

Advertisement

4 Zoning information

HP Virtual SAS Manager (VSM) is the software application used to configure the switch, and create
and manage hardware-based zone groups. These zone groups allocate resources for device load
balancing purposes and for selectively allowing access to data. For planning purposes, zone
groups and assignments can be pre-configured, even if servers or drives are not yet installed in
BladeSystem c-Class enclosure device bays or storage enclosure drive bays.
NOTE:
While zoning is created and managed through the VSM, the storage is configured,
formatted, and partitioned using software utilities such as the HP Array Configuration Utility (ACU),
HP Storage Management Utility (SMU), and Microsoft Disk Manager.

Types of zone groups

There are two types of zone groups:
Drive bay zone groups—Group together drive bays, which can be chosen from one or more
MDS600 storage enclosures or MDS600 storage enclosure drawers. Server bays assigned
this type of zone group have exclusive access to the drive bays included in the zone group
as if they are directly connected to those servers. Bay-based zoned storage environments such
as those using the MDS600 use drive bay zoning.
Switch port zone groups—Group together one or more SAS ports on the switch. Server bays
assigned this type of zone group have access to the controller enclosures or tape devices
connected to the ports included in the zone. Tape environments and shared storage
environments such as those using the MSA2000sa use switch port zoning. All tape drives in
a tape device will be accessible to any server that has access to the zone group. All LUNs in
the controller enclosure will be accessible to the assigned servers, unless controlled through
the storage management utility for the controller enclosure.

Key zoning configuration steps

Key zoning configuration steps include:
1.
Enabling/disabling Multi-initiator mode.
2.
Creating zone groups (switch-port based or drive-bay based).
3.
Assigning zone groups to servers.
IMPORTANT:
Assigned zone groups must reside on external storage enclosures that are connected to switch
ports that map to that server bay. For more information, see
mappings" (page
4.
Capturing the configuration for safekeeping. HP strongly recommends this step, especially in
single-domain configurations.
For more information about zoning, see the HP 3G Virtual SAS Manager User Guide, available
on the HP 3Gb SAS BL Switch page of the HP Manuals website
manuals.
38

Zoning information

When assigning zone groups to servers, certain restrictions are imposed.
39).
"Zoning requirements and device
http://www.hp.com/support/

Advertisement

Table of Contents
loading