The probability that a logical drive will fail depends on the RAID level setting.
A RAID 0 logical drive fails if only one physical drive fails.
For a RAID 1+0 logical drive, the failure situation is complex.
— The maximum number of physical drives that can fail without causing
failure of the logical drive is n/2, where n is the number of hard drives in the
array. This maximum is reached only if no failed drive is mirrored to any
other failed drive. In practice, a logical drive usually fails before this
maximum is reached. As the number of failed drives increases, it becomes
increasingly unlikely that a newly failed drive is not mirrored to a previously
failed drive.
— The failure of only two physical drives is enough to cause a logical drive to
fail if the two drives happen to be mirrored to each other. The risk of this
occurring decreases as the number of mirrored pairs in the array increases.
A RAID 5 logical drive (with no online spare) fails if two physical drives fail.
A RAID ADG logical drive (with no online spare) fails when three physical
drives fail.
At any given RAID level, the probability of logical drive failure increases as the
number of physical drives in the logical drive increases.
The graph in Figure F-1 provides more quantitative information. The data for this
graph is calculated from the mean time between failure (MTBF) value for a typical
physical drive, assuming that no online spares are present. If an online spare is added
to any of the fault-tolerant RAID configurations, the probability of logical drive
failure is further decreased.