1. Frame appliance enclosure as illustrated in Figures 7 and 8.
Note: If a wall covering is used to line the enclosure, then all
measurements must be from the surface of the covering.
2. Place the appliance into the framing and secure it.
Note: If appliance is to be raised above floor level, a platform
must be built to support the appliance.
3. Install the supply line to the appliance using a 1/2" NPT black
iron gas line terminating 2
pliance. The gas line must be installed through the lower left
side access point or alternate access hole in the bottom of the
appliance (see Figure 19, page 11).
4. Repack insulation around the gas line to cover any remaining
openings in the conduit sleeve. Prepare the incoming gas line
with teflon tape or pipe joint compound and hook-up incoming
gas line to the flexible gas line.
Note: If 1/2" NPT black iron pipe does not mate with fitting
at the end of flexible gas line, remove fitting and replace with
a 37 degree flare 3/4"-12, 1/2" NPT (female) fitting.
WARNING: When finishing appliance, do not overlap
combustible material onto the black front face. Brick,
tile or other noncombustible materials may be applied
to the face provided that any gap is between the mate-
rial used and the face is caulked with a noncombustible
caulking.
B
M36(B,H), M36P(B,H)
VM36(B,H), VM36P(B,H)
A
40
/
" (1020 mm)
3
8
B
21
/
" (543 mm)
3
8
C
41
1
/
" (1048 mm)
4
Figure 7 - Rough Opening for Installing in Wall
For more information, visit www.desatech.com
108795-01M
/
" above the bottom of the ap-
5
16
C
M42(B,H), M42P(B,H)
VM42(B,H), VM42P(B,H)
44
/
" (1121 mm)
3
8
23
/
" (587 mm)
1
8
48
1
/
" (1226 mm)
4
C
M36(B,H), M36P(B,H)
VM36(B,H), VM36P(B,H) VM42(B,H), VM42P(B,H)
A
24
B
73
C
52
D
17
Figure 8 - Corner Installation Guidelines
INSTALLING TRANSITION PIPE AND
STARTER COLLAR
The transition pipe and starter collar shown in Figure 9 are supplied
with the fireplace, unattached and ready for installation. Remove
the starter collar and set aside. Slide the transition pipe over the
vent collar and attach with a minimum of three screws. Replace the
starter collar over the transition pipe and attach using four screws
located on the leg stands (five used on the model M42). To install
B-vent piping, slide the first piece of B-vent over the transition pipe
and attach with either a minimum of two screws or other means
approved by the vent manufacturer.
A
Figure 9 - Installing Transition Pipe and Starter Collar
These Dimensions Allow for a 3/4"
Clearance at Sides and Back of
Fireplace. However, 0" Clearance
is Permitted
D
A
B
M42(B,H), M42P(B,H)
/
" (622.3 mm)
27
1
2
/
" (1876.4 mm)
83
7
7
8
/
" (1326 mm)
59
3
5
16
/
" (438.2 mm)
19
1
4
B-Vent Piping
Transition Pipe
Vent Collar
7 7
3/4" Clearance
Not Required
at Nailing
Flanges
/
" (700.1 mm)
9
16
/
" (2130.4 mm)
8
/
" (1506.6 mm)
16
/
" (495.3 mm)
1
2
Starter Collar