INSTALLATION
Continued
PRESSURE TESTING FIREPLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 27,
page 19).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP
supply tank valve.
3. Place manual ignition switch in the OFF
position.
4. Check all joints from equipment shutoff valve
to gas valve (see Figure 28 or 29). Apply
noncorrosive leak detection fluid to all joints.
Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light fireplace (see Operating Fireplace, page
25). Check all other internal joints for leaks.
7. Turn off fireplace (see To Turn Off Gas to
Appliance, page 27).
Manual Gas Valve
Figure 28 - Checking Gas Joints for
Natural Gas Fireplace
Equipment Shutoff Valve
Manual Gas Valve
Figure 29 - Checking Gas Joints for
Propane/LP Gas Fireplace
20
Equipment Shutoff Valve
Gas Meter
Propane/LP
Supply Tank
www.desatech.com