Dell DX6004S Hardware Owner's Manual page 29

Hardware owner's manual
Hide thumbs Also See for DX6004S:
Table of Contents

Advertisement

Table 1-1. LCD Status Messages
Code
Text
E1810
Hard drive ##
fault. Review
& clear SEL.
E1812
Hard drive ##
removed. Check
drive.
E1920
iDRAC6 Upgrade
Failed.
E1A14
SAS cable A
failure. Check
connection.
E1A15
SAS cable B
failure. Check
connection.
E1A1D
Control panel
USB cable not
detected.
Check cable.
E2010
Memory not
detected.
Inspect DIMMs.
E2011
Memory
configuration
failure.
Check DIMMs.
(continued)
Causes
The specified hard drive
has experienced a fault.
The specified hard
drive has been removed
from the system.
optional iDRAC6
upgrade has failed.
SAS cable A is missing
or bad.
SAS cable B is missing
or bad.
USB cable to the control
panel is missing or bad.
No memory was detected
in the system.
Memory detected, but is
not configurable.
Error detected during
memory configuration.
Corrective Actions
See "Troubleshooting a
Hard Drive" on page 149.
Information only.
See "Getting Help" on
page 161.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 161.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 161.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 161.
Install memory or reseat
memory modules. See
"Troubleshooting System
Memory" on page 145.
See "Troubleshooting
System Memory" on
page 145.
About Your System
29

Advertisement

Table of Contents
loading

Table of Contents