v System Security
v Start Options
v Advanced Setup
60
System x3200 M2 Types 4367 and 4368: User's Guide
This choice is on the Configuration/Setup Utility menu only.
Select this choice to set password. See "Using passwords" on page 62 for more
information about passwords.
– Administrator Password
This choice is on the full Configuration/Setup Utility menu only.
Select this choice to set or change an administrator password. An
administrator password is intended to be used by a system administrator; it
limits access to the full Configuration/Setup Utility menu. If an administrator
password is set, the full Configuration/Setup Utility menu is available only if
you type the administrator password at the password prompt.
– Power-on Password
Select this choice to set, change, or delete a power-on password.
Select this choice to view or change the start options. Changes in the start
options take effect when you restart the server.
You can enable or disable the hard disk drive self-monitoring, analysis, and
reporting technology (SMART) function.
You can set keyboard operating characteristics, such as the keyboard speed, and
you can specify whether the server starts with the keyboard number lock on or
off.
You can enable a virus-detecting test that checks for changes in the boot record
when the server starts.
– Startup Sequence Options
Select this choice to view the Startup Sequence Options menu. The startup
sequence specifies the order in which the server checks devices to find a boot
record. The server starts from the first boot record that it finds.
Select this choice to change values for advanced hardware features, such as
CPU options and PCI configuration.
Important: The server might malfunction if these settings are incorrectly
configured. Follow the instructions on the screen carefully.
This choice is on the full Configuration/Setup Utility menu only.
– CPU Options
Select this choice to view or change the options that control the behavior of
the microprocessor.
– PCI Bus Control
Select this choice to view or change the system resources that are used by
the installed PCI or PCI-Express devices.
– RSA II Settings
This choice is displayed only when a Remote Supervisor Adapter II SlimLine
is installed in the server.
Select this choice to view the DHCP IP address and settings and the Remote
Supervisor Adapter II SlimLine MAC address; to view or change the DHCP
control, static IP address, operating-system USB selections; and to save the
values and reboot the Remote Supervisor Adapter II SlimLine.
– Baseboard Management Controller (BMC) Setting
Select this choice to change the Intelligent Platform Management Interface
(IPMI) settings for the mini-BMC controller.