Table 1. Features and specifications
Microprocessor:
®
v Supports one Intel
Core
dual-core or Xeon
dual-core or
quad-core microprocessor
Note: Intel Virtualization Technology
(VT) is not available on the Core 2
Duo E4600; however, these
microprocessors can only run
paravirtualization.
v 2 MB, 6 MB, or 12 MB Level-2 cache
v 800, 1066, or 1333 MHz front-side
bus (FSB)
Memory:
v Minimum: 512 MB
v Maximum: 8 GB
v Types: PC2-5300 or PC2-6400, ECC
unbuffered double-data-rate 2
(DDR2) 667 or 800 MHz SDRAM
v Connectors: four dual inline memory
module (DIMM) connectors, two-way
interleaved
Drives (depending on the model):
v Diskette (optional): External or
internal USB FDD drive and memory
key
v Hard disk drive: Hot-swap SAS,
hot-swap SATA, or simple-swap
SATA
v One of the following SATA attached
optical drives:
– DVD-ROM
– Multiburner (optional)
Drive bays (depending on the
model):
v Two 5.25 in. half-high bays (one
optical drive installed)
v One 3.5 in. slim-high
removable-media drive bay (optional
diskette drive)
Four 3.5 in. or 2.5 in. slim-high hard
v
disk drive bays (some models)
v Eight 2.5 in. slim-high hard disk drive
bays (some models)
PCI expansion slots (depending on
the model):
v One PCI Express x8 slot
v One PCI Express x4 slot (x4 slot with
x1 electrical)
v One PCI-X 64-bit/133 MHz slot
Note: This PCI-X slot is enabled
when an optional PCI-X enablement
card is installed in the mini-PCI slot
on the system board. When no
mini-PCI-X enablement card installed,
this slot has no function.
v Two PCI 32-bit/33 MHz slots
4
System x3200 M2 Types 4367 and 4368: User's Guide
Fans:
2 Duo
Three speed-controlled fans.
Power supply:
One of the following power supplies:
v One or two redundant 430-watt (90-240
V ac)
v One non-redundant 401-watt (90-240 V
ac)
Size:
v Height: 438 mm (17.25 in.)
v Depth: 540 mm (21.25 in.)
v Width: 216 mm (8.5 in.)
v Weight: 16.3 kg (36 lb) to 25.2 kg (56
lb) depending upon configuration
Integrated functions:
v Mini-baseboard management controller
(mini-BMC)
v Broadcom BCM5722 10/100/1000
Ethernet controller on the system board
with RJ-45 Ethernet port
v One internal single-channnel (four ports
per channel) SAS/SATA controller
(mini-PCI slot)
v Two serial ports
v One parallel port
v Six-port Serial ATA controller
v Eight Universal Serial Bus (USB) v2.0
ports (two on front and four on rear, one
internal for optional tape drive, and one
internal for optional Remote Supervisor
Adapter II SlimLine)
v Onboard ATI ES1000 video controller
– Compatible with SVGA and VGA
– 64 MB DDR2 SDRAM video memory
Diagnostic LEDs:
v Fans
v Hard disk drives
v Memory
v Microprocessor
v PCI slots
v Power supply
v VRD
Acoustical noise emissions:
v Sound power, idling: 5.0 bel
v Sound power, operating: 5.3 bel
Environment:
v Air temperature:
– Server on: 10° to 35°C (50° to 95°F)
Altitude: 0 to 914.4 m (3000 ft)
– Server on: 10° to 32°C (50° to 89.6°F)
Altitude: 914.4 m (3000 ft) to 2133.6 m
(7000 ft)
– Server off: 10° to 43°C (50° to 109.4°F)
Maximum altitude: 2133.6 m (7000 ft)
– Shipping: -40° to 60°C (-40° to 140°F)
v Humidity (operating and storage):
– Server on: 8% to 80%
– Server off: 8% to 80%
Heat output:
Approximate heat output in British thermal
units (Btu) per hour:
v Minimum configuration: 630 Btu per hour
(185 watts)
v Maximum configuration: 1784 Btu per hour
(523 watts)
Electrical input:
v Sine-wave input (50 or 60 Hz) required
v Input voltage and frequency ranges
automatically selected
v Input voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
v Input voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
v Input kilovolt-amperes (kVA) approximately:
– Minimum: 0.20 kVA (all models)
– Maximum: 0.55 kVA
Notes:
1. Power consumption and heat output vary
depending on the number and type of
optional features that are installed and the
power-management optional features that
are in use.
2. These levels were measured in controlled
acoustical environments according to the
procedures specified by the American
National Standards Institute (ANSI) S12.10
and ISO 7779 and are reported in
accordance with ISO 9296. Actual
sound-pressure levels in a given location
might exceed the average stated values
because of room reflections and other
nearby noise sources. The declared
sound-power levels indicate an upper limit,
below which a large number of computers
will operate.