PRE-INSTALLATION
PREPARATION
Continued
Combustible Material
Left Side
Surround
(0" Min.)
Right Side
Surround
(0" Min.)
Wall In Front Of Glass
Perpendicular
Wall 2" Min.
From Opening
Minimum 1" Clearance from
Side (Only for See-Thru)
Figure 5 - Minimum Clearances
(See-Thru Shown)
Woodwork, such as wood trims, mantels and other
combustible materials should not be placed within
7" of the opening of this fireplace (see Figure 6).
Combustible material above projecting more than
1
/
" from the appliance's front face must not be
1
2
placed less than 15" from the opening of the appli-
ance, (ref. NFPA Standard 211 Sec. 7-3.3.3)
Combustible
Material May
Be Used
12" Min.
21" Min.
4"
Min.
15" Min.
7" Min.
Figure 6 - Mantel Clearances for
Peninsula and See-Thru Fireplaces
(Peninsula Shown)
56131-F
Drywall
TOP VIEW
2"
36" Min.
Drywall (Gypsum
Board, Sheetrock, Etc.)
Safe Zone for
Projection of
Combustible
Material
 x 4
Spacer
1
1
/
" Max.
2
UNIT
www.desatech.com
FRAMING
Once the final location has been determined, ob-
serving clearances for the vent termination, you
may construct framing using dimensions shown
in Figures 7 to 13 depending on your particular
installation
If the appliance is to be installed directly on carpeting,
0"
tile (other than ceramic), or any combustible mate-
rial other than wood flooring, the appliance must be
installed upon a metal or wood panel extending the
 x 4
full width and depth of the appliance. There are three
Stud
holes on each side of the bottom of the unit where
screws can be used to secure the unit to the floor.
The gas supply line may be connected through the
36"
side framing or alternately through the lower sub-
flooring or a platform base if provided (see Figures
10 and 11, page 8). Depending on installation, refer
to appropriate illustrations.
Figure 7 - Rough Opening for Installing
Platform
Must Be
Solid, Flat,
and Fully
Supported
* As required by design as long as
ceiling clearance is maintained.
Figure 8 - Rough Opening for Installing
Peninsula Fireplace on Platform
Peninsula Fireplace
3
39
/
"
4
Min.
39
3
/
" Min.
4
*
7