Installation; Wall Switch Installation - Desa (V)DVF36 Owner's Operation And Installation Manual

Direct-vent fireplace
Table of Contents

Advertisement

INSTALLATION

WALL SWITCH INSTALLATION

Since the VDVF36TPNEA/TSTEA series uses a 24
VAC current supplied from a transformer mounted
on the ignition module and is prewired for easy
connection to a wall switch (see Figure 34). The
(V)DVF36TPNA/TSTA models use a self gener-
ated millivolt current that allows you to activate
the gas control valve directly without the use of
normal household electricity (see Figure 35). Both
versions are supplied with a wall switch kit for ready
connection and mounting.
WARNING: Do not wire re-
mote wall switch to main power
supply (Standard 120v house-
hold current).
1. To remove the louvers, simultaneously pull
both top end spring latches towards the center
of the appliance until they are disengaged
from locating holes. Repeat for bottom spring
latches and pull louvers outward. Reverse the
procedure to install louvers back onto the ap-
pliance (see Figure 36).
2. Connect the 18 ga. wires from wall switch to
the gas control valve terminals marked TH
and TPTH or to the ignition module using the
pigtails and wire nut connectors supplied with
the appliance.
Route 4V (Supplied)
Through Electrical
Conduit Bushing
Electrode
Make Connections
with Wirenuts
(Supplied)
Transformer
Plug 10V AC
To Receptacle
G
P.
N
V2
SI
SW
L1
IND
TS
D
Figure 34 - Wall Switch Wiring Diagram,
Electronic Units
56131-F
E
A
Wall Switch
(Supplied)
G
P.
N
V2
L1
IND
TS
SI
SW
V1
D
Ignition
18 AWG
Control
Red Wire
Module
V1
www.desatech.com
CAUTION: Due to high tem-
peratures, make sure wires are
not touching upper firebox.
16AI
E
A
Route Millivolt Wires
(Supplied) Through Gas
Line Conduit Sleeve
Figure 35 - Wall Switch Wiring Diagram,
Note: If any of the original wire supplied must be
replaced, use type 18 AWG-105 degree C (25 feet
length maximum) or equivalent.
Figure 36 - Removing Louver
(Back
ELECTRICAL HOOKUP FOR
View)
OPTIONAL BLOWER ACCESSORY
Before blower accessory can be operated, the ap-
pliance outlet box must be properly connected to
a standard 120 VAC power source. This must be
done when the appliance is originally installed.
Refer to Wiring Diagrams on page 33.
An outlet box with two receptacles has been sup-
plied for your convenience and is located on the
lower right side of the appliance (see Figure 37,
page 22). The variable speed controller is mounted
on a magnetic base and may be positioned any-
where within an accessible distance behind the
louvered opening (see Figure 36).
To
Thermopile
16AI
Millivolt Units
Glass
Locating
Holes
Recommended
Blower Speed
Control Location
Spring
Latch
Wall Switch