Alarm Input
Connect this terminal to sensor devices, such as
an infrared sensor, door sensor, metal sensor,
manual switch, etc.
Input requirements
● No-voltage relay NPN open collector input
● Polarity of input detection can be selected
using a software
● Make/Break (500 ms and above)
● Circuit current at low level: 0.3 mA
● Applied voltage at high level: 3.3 V
Camera unit
DC3.3 V
Input 1
R
or Input 2
3.3 V
GND
(Alarm input equivalent circuit)
Alarm Output
Connect this terminal to annunciating devices,
such as annunciators, indicators, lights, buzzers,
etc.
Output requirements
● Equivalent to NPN open collector output (Set
the output put logic via the Internet Explorer)
● Allowable applied voltage: DC12 V and below
● Allowable inflow current: 50 mA
● Momentary (100 ms - 5000 ms) output
(Set time via the Internet Explorer
(A Pg. 50))
Camera unit
Output 1
or Output 2
GND
(Alarm output equivalent circuit)
Sensor
example (1)
VCC
R
OUT
0.3 mA
GND
Sensor
example (2)
Relay switch etc.
OUT
GND
Example of
annunciating
devices
DC 12 V
R
IN
GND
Note :
● Connect the GND cable of this camera to the
GND of the annunciating device.

Image adjustment

When the camera is mounted, adjust the image
settings while looking at the actual image.
Mounting the test monitor
Connect the [MONITOR] terminal of the camera
to the test monitor to adjust the camera shooting
direction, field angle and focus.
T When configuring, turn on the power of the
camera.
Test monitor
[MONITOR]
terminal
75 K terminated