Specifications - Vanguard SBVBN(A) Owner's Operation And Installation Manual

B-vent freestanding fireplace heater
Hide thumbs Also See for SBVBN(A):
Table of Contents

Advertisement

B-VENT FREESTANDING FIREPLACE

SPECIFICATIONS

Gas Type
Ignition
Manifold Pressure
Minimum Inlet Supply Pressure
Thermal Efficiency
Dimension, Inches/mm (HxWxD)
Fireplace*
Carton (Insert Only)
Weight, lbs/kg
Fireplace
Shipping
* When installed in Amity cast iron stove body (SCIVF Series and PSCIVF Series).
®
SBVBN(A)
17,000-24,000 Btu/h
Natural
Piezo
3.5" w.c.
4.5" w.c.
70%
27" x 26" x 25"
685.8 x 660.4 x 635mm
23" x 33" x 23"
584.2 x 838.2 x 584.2mm
70 lbs/31.8 kg
75 lbs/34 kg
26
SBVBP(A)
16,000-22,000 Btu/h
Propane/LP
Piezo
10.0" w.c.
11.0" w.c.
70%
27" x 26" x 25"
685.8 x 660.4 x 635mm
23" x 33" x 23"
584.2 x 838.2 x 584.2mm
70 lbs/31.8 kg
75 lbs/34 kg
105500

Advertisement

Table of Contents
loading

This manual is also suitable for:

SbvbpaSbvbnSbvbp

Table of Contents