Vanguard SBVBN(A) Owner's Operation And Installation Manual page 24

B-vent freestanding fireplace heater
Hide thumbs Also See for SBVBN(A):
Table of Contents

Advertisement

B-VENT FREESTANDING FIREPLACE
TROUBLESHOOTING
Continued
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas
• If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies,
paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These
fumes may mix with combustion air and create odors. These odors will disappear over time.
OBSERVED PROBLEM
Fireplace produces unwanted odors
Fireplace shuts off in use
Gas odor even when control knob is in OFF
position
Gas odor during combustion
Dark residue on logs or inside of fireplace
®
WARNING: If you smell gas
supplier's instructions.
POSSIBLE CAUSE
1. Gas leak. See Warning statement
above
1. High or gusting winds
2. Low line pressure
3. Pilot is partially clogged
4. Inner vent pipe leaking exhaust gasses
into system
5. Glass too loose and air tight gasket leaks
in corners after usage
6. Bad thermopile
7. Improper vent cap installation
1. Gas leak. See Warning statement
above
2. Control valve defective
1. Gas leak. See Warning statement
above
1. Improper log placement
2. Air holes at burner inlet blocked
3. Burner flame holes blocked
www.desatech.com
24
REMEDY
1. Locate and correct all leaks (see Check-
ing Gas Connections, page 13)
1. Fireplace has been tested for up to
40mph winds. However, extreme con-
ditions may occur. See Lighting Instruc-
tions on page 18.
2. Contact local propane/LP or natural gas
company
3. Clean pilot (see Cleaning and Mainte-
nance, page 21)
4. Locate and correct all leaks (see Check-
ing Gas Connections, page 13)
5. Tighten glass
6. Replace faulty component
7. Check for proper installation and free-
dom from debris or blockage
1. Locate and correct all leaks (see Check-
ing Gas Connections, page 13)
2. Replace control valve
1. Locate and correct all leaks (see Check-
ing Gas Connections, page 13)
1. Properly locate logs (see Installing Logs,
Lava Rock, and Glowing Embers, page 17)
2. Clean out air holes at burner inlets. Pe-
riodically repeat as needed
3. Remove blockage or replace burner
105500

Advertisement

Table of Contents
loading

This manual is also suitable for:

SbvbpaSbvbnSbvbp

Table of Contents