Product Dimensions; Anti-Tip Bracket; Electrical Requirements - Whirlpool GR556LRKB Installation Instructions Manual

30" (76.2 cm) electric freestanding range with self-cleaning, convection oven
Table of Contents

Advertisement

Cutoutdimensions/requirements
25"(63.5 cm) countertop d epthand
24"(61 cm)basecabinetdepth,
36"(91.4 cm) countertop h eight
_
jFor
minimum
I
2....
--clearancn
to the
30" (76.2 cm) rain.
top of thecooktop,
t8°(46.7 cm)
upper cabinet
I
to counterlop
_
30" 76.2 cm)
_
]
opening width
_'_
I
I
4" 10.2 cm
m n. C earance from f
both sides ofrange
toside wallorother
combustible
material.
i
I
i
receptical or
unction box
-
• 8
20.3cmto
22" 55.9
cm)
from
ethercab net,
7" 17.8cm)max.
from f nor.
_ required between
cutout and cabinet
door or hinge.
I
1 -_
* Note: 24"(61cm)rain.when bottom ofwood ormetal c abinet is
protectedby
notless than 1/4"
(0.64 cm)
flame retardant millboard
covered with not lessthan No.28MSG sheet s teel, 0 .015"0.4mm
stanessstee,0.024"0.6mm a umnora or0.020" ( 0.5ram)copper.
30" 76.2
cm)
rain.clearance between thetop ofthe
cooking platform
and thebottom o an
unprotected
wood ormetacabnet.
Productdimensions
43" (109.2 cm)
overall height
36" (91.4 cm)
cooktop
height with
feet loosened
1=1/2 turns
30"
76.2 cm)
27-3/4"
_
J
w dth
(70.5cm)
]
depth
"_
When installed in a 24" 61 cm) base cabinet with 25" (63.5 cm)
countertop--
font o oven door protrudes1-7/8" 4.8 cm beyond
24" (61 cm) base cabinet.
Anti-tipbracket:
.......
The floor anti-tip bracket
i
_
MUST be installed.To
install
"_
, _
the anti-tip bracket shipped
_
_.';_,_
with the range, see Page 7 and
the anti-tip bracket template.
Electrical
requirements
Electrical Shock Hazard
Electrically ground range.
Failure to follow these
instructions can result in death,
fire, or electrical shock.
If codes permit and a separate
ground wire is used, it is
recommended that a qualified
electrician determine that the ground
path is adequate.
Do Not ground to a gas pipe.
Check with a qualified electrician if
you are not sure range is grounded.
Do Not have a fuse in the neutral or
ground circuit.
A=
When a four-wire or three-wire,
single- phase, 120/240wolt, 60-Hz, AC-
only, electrical supply is available, a 50-
ampere maximum circuit protection is
required, (or, if specified on the
model/serial
rating plate, when a four-
wire or three-wire, single-phase
120/208-volt, 60 Hz, AC-only electrical
supply is available, a 40-ampere
maximum circuit protection is required),
fused on both sides of the line. A time-
delay fuse or circuit breaker is
recommended. The model/serial
rating
plate is located on the oven frame
behind the drawer.
B=
Wire sizes and connections must
conform to the requirements of the
National Electrical Code, ANSI/NFPA
70 -- latest edition* or CSA Standard
C22.1, Canadian Electrical Code,
Part 1 -- latest edition** and all local
codes and ordinances for the kilowatt
rating of the range.
Copies of the standards listed may be obtained
from:
* National
Fire Protection
Association
Batterymarch
Park
Qoincy, Massachusetts
02269
** CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131.5575

Advertisement

Table of Contents
loading

Table of Contents