Lexicon REFLEX - REV User Manual page 46

Hide thumbs Also See for REFLEX - REV:
Table of Contents

Advertisement

Other MIDI Notes
• In Front Panel Operation, registers can be
"cleared" and "uncleared" to allow regis-
ters to be skipped in a footswitch-con-
trolled sequence. Cleared registers can-
not be selected via MIDI.
Information regarding the cleared or un-
cleared state of a register is not saved
when a register is exported via MIDI.
Likewise, when a MIDI dump is received
by Reflex, al registers are automatically
"uncleared".
• MIDI errors cause the display of the mes-
sage "Er" followed by a number (1-3) to
indicate the following:
1
Received incorrect checksum
2
Received incorrect number of bytes
3
Timed out waiting for SysEx message
This display will remain until you move
any front panel knob or button.
• During reception of a dump or load com-
mand, Reflex displays one of the following
messages:
dA Dumping all registers from Reflex
dC Dumping current effect from Reflex
dS Dumping a single Reflex effect
LA Loading all Reflex registers
LC Loading "current"
LS Loading a single Reflex effect
43
Using MIDI System Exclusive Data
Setups can be created using MIDI Sys-
tem Exclusive (SysEx) data to allow you to
use Reflex with remote controllers such as
the Lexicon MRC, or other commercially
available computer editing software.
MIDI implementation data, including Sys-
tem Exclusive documentation is available to
assist experienced programmers in develop-
ing software for use with Reflex. This can be
obtained directly from Lexicon. Request:
Reflex MIDI Implementation Details.