PRO (Register Protect)
PRO has four options:
OFF (no protection)
INTERNAL (internal registers are protected)
CARTRIDGE (cartridge registers are protected)
INT & CART (both internal and cartridge
registers are protected)
When registers are protected, they cannot be copied
to, moved to, cleared, or otherwise erased. Blank
registers can still be copied or moved to.
DEF (Default)
DEF selects the power-up default mode. Advancing
the slider selects a program to load automatically when
power is interrupted, then restored. Press MACH to
select a default program for the other machine. (When
shipped, DEF is set to "Off.")
Page Three
This page is used to change the name of the current
program.
SEL (Character Select)
SEL selects the character to change.
CHG (Character Change)
CHG changes the selected character. Symbols are at
the bottom of the range, numerals in the middle, and
characters at the top. To enter the name change, hold
down STO and press REG.
Page Four
Page four contains controls which allow you to set up
10 MIDI patches. Each register can have a unique
set of 10 patches.
SEL (Patch Select)
SEL chooses which of the 10 patches will be edited.
SRC (Source)
SRC selects the MIDI controller or event that will be
patched to the 480L parameter or event.
DST (Destination)
DST chooses the 480L parameter or event to be
controlled by the MIDI controller or event selected with
SRC.
Appendix E: Control Mode Reference
SCL/LOW (Scaling Factor/Low Note)
When SRC is set to a MIDI controller, last note, or last
velocity, this slider sets the scaling. Scaling determines
the relationship between settings of the MIDI controller
and the parameter which is under its control. Scaling
ranges from -200% through +200%.
In the sampler and doppler programs, when SRC is set
to NOTE EVENT, this control sets the LOW NOTE.
PRM/HIGH (Parameter/High Note)
When SRC is set to a MIDI controller, last note, or last
velocity, this slider allows control of the parameter
selected with DST. This is particularly useful when
trying to set the correct SCL value.
In the sampler and doppler programs, when SRC is set
to NOTE EVENT, this control sets the HIGH NOTE.
Page Five
Page Five contains the corresponding register table
and the MIDI channel selection control.
AUTO
Sets the two states of SysEx Automation: Off or On
(Transmit). Do not leave this slider set to TRANSMIT
when performing SysEx bulk dumps or loads.
CHL (MIDI Channel)
CHL sets the MIDI channel for program changes and
patches.
Note: Remember that the MIDI channel and corre-
sponding register table are set separately for each
machine when the 480L is in Split or Cascade
modes.
PGM (MIDI Program Change Number)
PGM has a range of 0 - 127, and sets the MIDI program
change number for the corresponding register table.
TBL (Corresponding Register Table)
TBL chooses the 480L program or register to link to the
MIDI program change number selected with PGM.