Yaesu FT-950 - MENU MODE LIST Manual

Yaesu FT-950 - MENU MODE LIST Manual

Hide thumbs Also See for FT-950 - MENU MODE LIST:

Advertisement

M
M
ENU
ODE
The Menu system of the FT-950 provides extensive customization capability, so you can set up your transceiver just the
way you want to operate it. The Menu items are grouped by general utilization category, and are numbered from "001 AGC
FST DLY" to "118 TGEN EMRGNCY
FST DLY
FST DLY
FST DLY
FST DLY
118 TGEN EMRGNCY".
118 TGEN EMRGNCY
118 TGEN EMRGNCY
118 TGEN EMRGNCY
1. Press the [ MENU ] button momentarily, to engage the

Menu mode.

The display will show the Menu Number, Menu Group
Name, and Menu Item. Press the [ SELECT ] knob
momentarily to toggle the display between "Menu
Number & Menu Group Name" and "Menu Item". The
Multi-Display Window shows the current setting of the
currently selected Menu item.
2. Rotate the [ SELECT ] knob to select the Menu item
you wish to modify.
3. Rotate the [ CLAR/VFO-B ] knob to change the cur-
rent setting of the selected Menu item.
A
:
DVICE
Press the [ CLEAR ] button (located the upper right of
the [ SELECT ] knob) momentarily to reset the selected
Menu item to the factory default value.
4. When you have finished making your adjustments,
press and hold in the [ MENU ] button for one second
to save the new setting and exit to normal operation. If
you only momentarily press the [ MENU ] button, the
new settings will not be retained.
M
M
ENU
You may reset all the Menu settings to their origi-
nal factory defaults, if desired.
1. Turn the front panel [ POWER ] switch off.
2. Press and hold in the [ MENU ] button, and while
holding it in, press the [ POWER ] switch to turn
the transceiver back on. Now release the
[ MENU ] button.
Page 104
U
SING THE
R
ODE
ESET
M
ENU
[ CLEAR ] Button
[ MENU ] Button
[ SELECT ] Knob
Press
FT-950 O
001 AGC
001 AGC
001 AGC
001 AGC
[ CLAR/VFO-B ] Knob
Menu Number
Menu Group Name
Menu Setting
Menu Item
Menu Setting
M
PERATING
ANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Yaesu FT-950 - MENU MODE LIST

  • Page 1 The Menu system of the FT-950 provides extensive customization capability, so you can set up your transceiver just the way you want to operate it. The Menu items are grouped by general utilization category, and are numbered from “001 AGC 001 AGC 001 AGC 001 AGC...
  • Page 2 ROUP UNCTION VAILABLE ALUES EFAULT ETTING 001 AGC FST DLY 20 ~ 4000 msec ( 20 msec/step ) 300 msec 20 ~ 4000 msec ( 20 msec/step ) 002 AGC MID DLY 700 msec 20 ~ 4000 msec ( 20 msec/step ) 003 AGC SLW DLY 3000 msec DISPLAY...
  • Page 3: Table Of Contents

    ROUP UNCTION VAILABLE ALUES EFAULT ETTING MODE-DATA 050 DATA DT GAIN 0 ~ 100 MODE-DATA 051 DATA OUT LVL 0 ~ 100 30 ~ 3000 msec ( 10 msec/step ) MODE-DATA 052 DATA VOX DLY 300 msec MODE-DATA 053 DATA V GAIN 0 ~ 100 –3000 ~ +3000 Hz ( 10 Hz/step ) MODE-DATA...
  • Page 4 ROUP UNCTION VAILABLE ALUES EFAULT ETTING TX AUDIO 091 TAUD EQ1 FRQ OFF/100 ~ 700 Hz ( 100 Hz/step ) TX AUDIO 092 TAUD EQ1 LVL –20 ~ +10 TX AUDIO 093 TAUD EQ1 BW 1 ~ 10 OFF/700 ~ 1500 Hz ( 100 Hz/step ) TX AUDIO 094 TAUD EQ2 FRQ TX AUDIO...
  • Page 5 AGC G DISPLAY G ROUP ROUP 001 AGC FST DLY 004 DISP COLOR Function: Sets the delay time for the AGC FAST mode. Function: Selects the Display color when the optional Data Available Values: 20 ~ 4000 msec (20 msec/step) Management Unit (DMU-2000) is connected.
  • Page 6 DISPLAY G DVS G ROUP ROUP 014 DVS RX LVL 011 DISP RTR STU Function: Sets the audio output level from the optional Function: Selects the starting point of your rotator DVS-6 Voice Memory Unit. controller’s indicator needle. Available Values: 0 ~ 100 Available Values: 0/90/180/270°...
  • Page 7 KEYER G GENERAL G ROUP ROUP 024 GENE ANT SEL 019 KEY CW MEM1 Function: Sets the method of antenna selection. Function: Permits entry of the CW message for message Available Values: bAnd/rEG register 1. Default Setting: bAnd Available Values: tyP1/tyP2 bAnd: The antenna is selected in accordance with the op- Default Setting: tyP2 erating band.
  • Page 8 GENERAL G MODE-CW G ROUP ROUP 037 A1A F-TYPE 032 GENE uT DIAL Function: Selects the desired keyer operation mode for Function: Selects the μ-TUNE mode. the device connected to the front panel’s KEY jack. Available Values: StP1/StP2 Available Values: OFF/buG/ELE/ACS Default Setting: StP1 Default Setting: ELE StP1: Activates the μ-TUNE system using “COARSE”...
  • Page 9 MODE-CW G ROUP 041 A1A CW AUTO 045 A1A PITCH Function: Enables/disables CW keying while operating Function: Adjusts your preferred CW tone pitch. on SSB. Available Values: 300 ~ 1050 Hz (50 Hz/step) Available Values: OFF/50/On Default Setting: 700 Hz Default Setting: OFF 046 A1A WEIGHT OFF: Disables CW keying while operating on SSB.
  • Page 10: Data Dt Gain

    MODE-DATA G MODE-FM G ROUP ROUP 050 DATA DT GAIN 056 F3E MIC Function: Sets the data input level from the TNC to the Function: Sets the microphone gain for the FM mode. AFSK modulator. Available Values: Ur/0 ~ 100 Available Values: 0 ~ 100 Default Setting: 50 Default Setting: 50...
  • Page 11: J3E Tx Bpf

    MODE-SSB G RX GENERAL G ROUP ROUP 064 J3E TX BPF 067 RGEN NB 1 LVL Function: Selects the audio passband of the DSP modula- Function: Adjusts the noise blanking level of the IF Noise tor on the SSB mode. Blanker for short duration pulse noise.
  • Page 12: Scp 1.8 Fix

    SCOPE G ROUP DVICE This group’s adjustment has no effect if the optional DMU-2000 Data Management Unit is not connected. 073 SCP 1.8 FIX 079 SCP 18.0 FIX Function: Selects the scan start frequency of the FIX mode Function: Selects the scan start frequency of the FIX mode Spectrum Scope while monitoring on the 160 m amateur Spectrum Scope while monitoring on the 17 m amateur band.
  • Page 13: Tun Dialstp

    TUNING G TX AUDIO G ROUP ROUP 084 TUN DIALSTP 091 TAUD EQ1 FRQ Function: Setting of the Main Tuning Dial knob’s and the Function: Selects the center frequency of the lower range [ CLAR/VFO-B ] knob’s tuning speed on the SSB, CW, for the parametric microphone equalizer.
  • Page 14 TX AUDIO G ROUP 103 TAUD PE2 FRQ 097 TAUD EQ3 FRQ Function: Selects the center frequency of the high range Function: Selects the center frequency of the middle range for the parametric microphone equalizer. for the parametric microphone equalizer when the speech processor is activated.
  • Page 15 TX GENERAL G ROUP 109 TGEN PROCLVL 114 TGEN VOX SEL Function: Sets a compression level of the Speech Proces- Function: Selects the audio input source for triggering TX sor. during VOX operation. Available Values: 1 ~ 100 Available Values: nic/dAtA Default Setting: 50 Default Setting: nic nic (MIC):...

Table of Contents