Factory Reset; Expression Pedal Calibration - DigiTech RP300 User Manual

Modeling guitar processor
Hide thumbs Also See for RP300:
Table of Contents

Advertisement

REVLVL (Reverb Level) - The LFO controls the Reverbs Mix Level.
VOLPRE (Volume Pre) - The LFO controls the Volume after the Amp Modeling but before
the Effects.
VOLPST (Volume Post) - The LFO controls the Volume at the end of the Effects chain.
4. Rotate the Number 3 Knob to select the minimum value the assigned parameter will
reach at the bottom turn around point for the LFO (not available when volume is the
assigned parameter).
5. Rotate the Number 4 Knob to select the maximum value the assigned parameter will
reach at the top turn around point for the LFO (not available when volume is the assigned
parameter).
6. Rotate the Number 5 Knob to select the speed at which the LFO will oscillate from the
minimum to the maximum value.
7. Store your LFO assignment to your Preset. See page 9 for more information on the storing
procedure.

Factory Reset

This function resets the RP300 to its original factory settings.This procedure will erase all cus-
tom user Presets, and recalibrate the Expression Pedal.
ATTENTION: Performing this function will erase all user-programmed data. All such
data will be lost forever! Be sure you want to erase the memory and start
fresh before continuing with this procedure.
The procedure for performing a Factory Reset is as follows:
1. Disconnect the power supply from the RP300.
2. Press and hold the Select button while re-connecting the power to the RP300.
3.When the display shows RST
The display will read RESET indicating that the RP300 has reset the original factory set-
tings. At this point, the RP300 will automatically advance to the Expression Pedal calibration
menu. Follow steps 4 through 7 of the Expression Pedal calibration section.

Expression Pedal Calibration

The Expression Pedal on the RP300 needs to be recalibrated for use after a factory reset has
been performed.This calibration procedure is automatically entered after a factory reset pro-
cedure. In the event the Pedal's calibration fails, or if the Pedal does not function properly, it
can be re-calibrated using the Pedal Calibration procedure.This will not erase the User
Presets.The procedure for Calibrating the Expression Pedal is as follows:
1. Disconnect the PS0913B power supply from the power jack on the RP300.
2. Press and hold the Down Footswitch while re-connecting the power.
3. Continue to hold the Down Footswitch until the Display briefly reads CALIB (calibra-
tion).
4.When the Display reads TOE DN, rock the Expression Pedal forward to the toe down
position.
5. Press any Footswitch and the Display now shows TOE UP.
6. Rock the Expression Pedal back to the toe up position.
7. Press any Footswitch.The RP300 will then enter the V-Switch Sensitivity adjustment menu
and the Display will read VSWTCH.
8. If you do not wish to adjust the V-Switch sensitivity, press any Footswitch and the RP300
will return to Performance Mode and the Expression Pedal is now calibrated.
Note: If the Display shows ERROR, an error has occurred and steps 4 through 8
should be repeated.