Delta Electronics Network Device VFD-S User Manual page 87

Compact low-cost easy-to-use general-purpose ac motor drive
Table of Contents

Advertisement

Chapter 5 Parameters|VFD-S Series
2-05
Loss of ACI Signal (4-20mA)
Settings
This parameter is only effective when the Source of Frequency is commanded by a 4 to
20mA signal. The ACI input is considered lost when the ACI signal falls below 2mA.
2-06
Analog Auxiliary Frequency Operation
Settings
This parameter is used to determinate that the analog signal to overlap is 0~10V (AVI) or
4~20mA (ACI).
To make sure the short PIN of J1 on the panel is correct position before setting this parameter.
5-30
d0
Decelerate to 0 Hz
d1
Coast to stop and display "EF"
d2
Continue operation by last frequency command
d0
Disable
d1
Enable + AVI (0~10V)
d2
Enable + ACI (4~20mA)
Factory Setting: d0
Factory Setting: d0
Revision August 2008, SE09, SW V2.61