Delta Electronics Network Device VFD-S User Manual page 113

Compact low-cost easy-to-use general-purpose ac motor drive
Table of Contents

Advertisement

Chapter 5 Parameters|VFD-S Series
Pr.6-08 to 6-10 store records of the three most recent faults that had occurred. Use the reset
key to reset the drive when the fault no longer exits.
5-56
d20
Software protection enable (codE)
d21
Reserved
d22
CPU failure (cF3.1)
d23
CPU failure (cF3.2)
d24
CPU failure (cF3.3)
d25
CPU failure (cF3.4)
d26
CPU failure (cF3.5)
d27
CPU failure (cF3.6)
d28
CPU failure (cF3.7)
d29
Hardware protection failure (HPF.1)
d30
Hardware protection failure (HPF.2)
d31
Hardware protection failure (HPF.3)
d32
Communication time-out (CE10)
d33
Reserved
d34
Software error (SErr)
d35
Reserved
d36
PID error (Pld)
d37
Reserved
d38
Phase loss (PHL)
Revision August 2008, SE09, SW V2.61

Hide quick links: