Download Print this page
Samsung SDP-950STA Reference Manual

Samsung SDP-950STA Reference Manual

Sdp series high resolution digital presenter rs-232c reference
Hide thumbs Also See for SDP-950STA:

Advertisement

Before attempting to operate this product, Please read the instructions carefully.
Before attempting to operate this product, Please read the instructions carefully.
HIGH RESOLUTION DIGITAL PRESENTER
HIGH RESOLUTION DIGITAL PRESENTER
RS-232C REFERENCE
RS-232C REFERENCE
SDP Series
SDP Series
SDP900DXA
SDP950DXA/STA
SDP990DXA
www.samsungpresenter.com
www.samsungpresenter.com

Advertisement

loading

Summary of Contents for Samsung SDP-950STA

  • Page 1 HIGH RESOLUTION DIGITAL PRESENTER HIGH RESOLUTION DIGITAL PRESENTER RS-232C REFERENCE RS-232C REFERENCE SDP Series SDP Series SDP900DXA SDP950DXA/STA SDP990DXA Before attempting to operate this product, Please read the instructions carefully. Before attempting to operate this product, Please read the instructions carefully. www.samsungpresenter.com www.samsungpresenter.com...
  • Page 2 RS232C PC-side FlowChart Basic Flow - BaudRate: 9600bps - Parity Bit: No Parity Send 6-byte to MICOM - Stop Bit Length: 1-bit [start_code(0xB0)+command code - Character Length: 8-bit (4-byte)+stop_code(0xBF)] - Start Code: 0xB0 - Stop Code: 0xBF - Command Code: 4-byte Receive 6-byte from MICOM (1st Rx data==0xB0) &(6th Rx data==0xBF)
  • Page 3: Rs232C Command Code

    RS232C Command Code PC Transmit Data to MICOM PC Receive Data from MICOM Command Remark 0 x 01 0 x 00 0 x 05 0 x 00 0 x 01 "ACK data" 0 x 05 0 x 00 0 x 02 0 x 00 0 x 05 0 x 00...
  • Page 4 RS232C Command Code PC Transmit Data to MICOM PC Receive Data from MICOM Command Remark Freeze ON 0 x 00 0 x 05 0 x 00 "ACK data" 0 x 05 0 x 00 0 x 12 0 x 12 Freeze OFF 0 x 00 0 x 0A...
  • Page 5 RS232C Command Code PC Transmit Data to MICOM PC Receive Data from MICOM Command Remark Focus Far 0 x 00 0 x 05 0 x 00 "ACK data" 0 x 05 0 x 00 0 x 25 0 x 25 Focus Near 0 x 00 0 x 0A...
  • Page 6 RS232C Command Code PC Transmit Data to MICOM PC Receive Data from MICOM Command Remark Set-Status(Normal) 0 x 61 0 x 00 0 x 00 0 x 00 0 x 61 "ACK data" Status(MSB) Status(LSB) Bit definition of Status Set-Status(Digital) 0 x 62 0 x 00 0 x 00...
  • Page 7 RS232C COMMAND CODE Bit Definition of "ACK data" (0,0,0,0,1): Set is executing command by panel-key (0,0,0,1,0): Set is executing command by remocon (0,0,1,0,0): Set is executing command by RS232C (0,1,0,0,0): Set is executing command by USB (1,0,0,0,0): Set is executing command by MOUSE Acknowledgement Bit ("0": no-ACK, "1": ACK) Status Bit Definition by Message-Status Command (0,0,0,0,1): Set is executing command by panel-key...
  • Page 8 RS232C Command Code Status Bit Definition by Set-Status Command - LSB 8bit (0): lamp all Off (0,1): upper lamp ON (1,0): lower lamp ON (0,0,0): internal input (1,0,1): NO SYNC (EXT1) (1,0,1): NO SYNC (EXT2) (1,1,0): external 1 input (1,1,1): external 2 input (0): positive mode (1): negative mode - MSB 8bit...
  • Page 9 RS232C COMMAND CODE Status Bit Definition by Set-Status(Digital) Command - LSB 8bit Divide position information (0,0):shift1 (0,1):shift2 (1,0):shift3 Divide or Recall number information (0,0,0,1): number1 (0,0,1,0): number2 (0,1,1,1): number7 (1,0,0,0): number8 - MSB 8bit (0): image divide OFF (1): image divide ON (0): 3X3 multi-screen OFF (1): 3X3 multi-screen ON (0,0):image rotate OFF (0,1):image rotate 90...
  • Page 10 MEMO...
  • Page 11 MEMO...
  • Page 12 HEAD OFFICE: SAMSUNG TECHWIN CO., LTD SAMSUNG OPTO-ELECTRONICS UK LTD (SOUK) 145-3 Sangdaewon 1-Dong, Jungwon-Gu, Sungnam, Samsung House,1000 Hillswood Drive Hillswood Business Kyungki-Do,Korea 462-703 Park Chertsey Surrey KT16OPS TEL : 82-31-740-8137~8141 TEL :44-(0)1932-45-5308 FAX :44-(0)1932-45-5325 FAX : 82-31-740-8145 U.S.A OFFICE: SAMSUNG OPTO-ELECTRONICS AMERICA, INC.

This manual is also suitable for:

Sdp900dxaSdp950dxaSdp990dxa