Water Level Probes - Vulcan-Hart VSX3E Service Manual

Vulcan vsx3e steamers: supplementary guide
Table of Contents

Advertisement

VSX SERIES STEAMER - REMOVAL AND REPLACEMENT OF PARTS
5. Disconnect the steam lines on the top right and
left side of the tank, the water fill tube, the drain
line, then the delime line at the bottom left
corner.
(Gas Model Shown)
6. Electric Models Only - For gas models proceed
to step 7.
A. Remove the heater lead wires, control and
high limit thermostat bulbs, then remove the
heater from the tank.
B. To remove tank, loosen the nut on the left
side mounting stud of the tank and remove
the two nuts from the mounting studs on the
right side of the tank.
(Electric Model Shown)
C. Push the right side of the tank toward the
rear of the unit enough to clear the studs
from the mounting bracket then, pull tank
toward the right to remove.
D. Reverse the procedure to install and check
unit for proper operation.
7. Gas Model Only
A. Remove the burner assembly and place to
the side.
B. Remove the bolts that secure the manifold
to the burner box frame and place to the
side.
C. Remove the surface high limit and the
control thermostat bulb from the tank.
D. Remove the combination Left side and Rear
panel as outlined under "COVERS AND
PANELS".
8. Remove the nuts and washers from studs on
each side of the tank that secure it to the steam
cavity and lift the steam generator tank out.
9. Reverse procedure to install and check unit for
proper operation.

WATER LEVEL PROBES

WARNING: DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT
BOX INDICATING THE CIRCUIT IS BEING
SERVICED.
1. Remove the top cover as outlined under
"COVERS AND PANELS".
2. Disconnect the lead wire to water level probes.
Page 14 of 40